R123 Refrigerant 50kg

$684.00 Price drop reminder
  • Brand: Wula
  • Net Weight: 20 kg
  • Availability: In Stock

Total $684.00
R123 (dichlorotrifluoroethane, HCFC-123) for Trane refrigeration unitsrefrigerant, not rightR11The refrigerant is replaced in a blood exchange manner.

Relevant information:
R123 Safety Technical Specification (MSDS)

Use of R123: It is used as a refrigerant in large central air conditioning centrifugal chillers (common such as Trane air conditioning units), and can also replace R11 and R113 for high-grade applications.Optical glass cleanerblowing agentand solvents.
R123 Specifications: 50kg, 100kg, 250kg

R123 physical properties
Molecular weight: 152.93
Critical temperature: 183.7℃
Melting point: -107℃
Critical pressure: 3.673
Boiling point: 27.6℃
Critical density: 0.549g/cm3
Relative density (water =1): 1.458
Evaporation potential at boiling point: 171.0KJ/Kg
Relative vapor density (air =1): 5.3
Solubility in water (25℃)W%: 0.39
Saturated vapor pressure (25℃): 96KPa
PH value: neutral
Specific heat (liquid 25℃): 0.985KJ/Kg.℃
Purity: ≥99.8%

R123 Environmental parameters
Ozone Destruction Potential (ODP): 0.020
Global Warming Coefficient (GWP): 77
Atmospheric lifetime (years): 1.3

Regulatory and compliance status (R123 / Dichlorotrifluoroethane (HCFC-123)) — phase-out in progress

R123 (Dichlorotrifluoroethane (HCFC-123)) belongs to the hydrochlorofluorocarbons (HCFC), with an ODP of 0.02, and is a Class II controlled substance under the Montreal Protocol, currently subject to the global phase-out schedule. Developed countries halted production and import in 2020; developing countries (including China) are advancing according to the schedule, with servicing stock tightening year by year. The following are the regional status as of 2026.

Product identity

R123 Dichlorotrifluoroethane (HCFC-123)
Safety class
B1
Type
HCFC

EU

  • RegulationOzone-Depleting Substances Regulation (EC) 1005/2009
  • StatusVirgin HCFC no longer placed on the market
  • ServicingUse of reclaimed product permitted until 2030 (for some equipment types)
  • For R123No supply of virgin product; servicing must use reclaimed product and must be performed by certified personnel

US

  • RegulationClean Air Act Title VI + SNAP program
  • StatusProduction and import of virgin HCFC halted from 2020-01-01
  • Existing stockReclaimed product can be used for the maintenance of existing equipment
  • For R123Only reclaimed product available; supply and prices continue to tighten

China

  • RegulationRegulations on the Administration of Ozone-Depleting Substances (2024 revision) + National Phase-out Plan
  • Schedule67.5% baseline reduction by 2025, 97.5% by 2030, with only a minimal amount retained for servicing use after 2040
  • QuotaAnnual quota licensing for production and use, decreasing year by year
  • For R123Supplied within quota; procurement must be filed; servicing use given priority
  • Domestic procurement qualificationMust be filed in the “Ozone-Depleting Substances Information Management System”; suppliers must verify the filing

Japan

  • RegulationOzone Layer Protection Act + Act on Rational Use and Proper Management of Fluorocarbons
  • StatusHCFC is essentially abolished, with only reclaimed product in circulation
  • For R123No supply of virgin product; must be retrofitted or replaced
Other countries and regions (grouped by the Kigali Amendment)

Apart from the four columns of EU / US / China / Japan, the global 170+ Kigali parties all comply under the A5 (developing countries) / non-A5 (developed countries) groupings of the Montreal Protocol, and none impose equipment-level bans. The grouping determines the HFC reduction pace and is unrelated to geography — for example, the Middle East Gulf and India belong to A5 Group 2, while Brazil, Mexico and Chile belong to A5 Group 1 (same group as China). The table below is a quick reference for the groupings of major markets:

GroupingHFC reduction paceMajor countries / regions (representative)
A5 Group 1
(developing countries, including China)
2024 freeze → 10% reduction by 2029 → 30% by 2035 → 50% by 2040 → 80% by 2045Brazil, Argentina, Chile, Colombia, Peru, Mexico, South Africa, South Korea, Thailand, Indonesia, Malaysia, Vietnam, Egypt, Nigeria, etc. (about 140 countries in total)
A5 Group 2
(high-ambient-temperature group, HAT)
2028 freeze → 10% reduction by 2032 → 20% by 2037 → 30% by 2042 → 85% by 2047India, Bahrain, Iran, Iraq, Kuwait, Oman, Pakistan, Qatar, Saudi Arabia, United Arab Emirates
Other non-A5
(developed countries, except EU/US/Japan)
85% reduction by 2036 / reduced to 15% by 2050Canada, Australia, New Zealand, Switzerland, Norway, United Kingdom, Russia* (first two steps delayed: 5% by 2020, 35% by 2025), etc.

For R123: a controlled substance in the phase-out process, with supply tightening year by year and prices rising. For the complete list of Parties and groupings, refer to the UNEP Ozone Secretariat (data version 2026.09).

GWP (100-year, on-site property basis)
77 (IPCC AR4)
ODP
0.02 (ozone-depleting substance, controlled under the Montreal Protocol)
Safety group (ASHRAE)
B1
Chemical family
HCFC
Buyer conclusion: R123 is an HCFC-class controlled substance with ODP 0.02 and GWP 77, currently in the global phase-out process, with supply tightening year by year and prices rising, and it can no longer be used in new equipment. Developed countries halted production and import of virgin product in 2020; China, under its National Phase-out Plan, reduces the baseline by 67.5% in 2025 and 97.5% in 2030. The EU, US and Japan all permit only reclaimed product for the maintenance of existing equipment. Recommendation: select an alternative refrigerant directly for new projects (R32, R454B, R513A or a hydrocarbon refrigerant); if existing equipment still uses R123, a retrofit should be planned in advance (noting verify lubricant compatibility and system compatibility). Domestic procurement must be filed in the “Ozone-Depleting Substances Information Management System”.

Thermophysical properties

Normal boiling point (1 atm)
27.8 °C
Saturation temp. (°C)-50-40-30-20-10102030405060
Saturation pressure (bar abs)0.01770.03580.06750.120.20250.50570.75611.09581.54472.12462.8589

Data taken from published pressure–temperature tables and interpolated; for selection reference only — do not use for safety-critical design, commissioning or charging calculations. The equipment manufacturer's requirements and primary references prevail. Refrigerant pressure–temperature tool

Regulatory data updated: 2026-09-17 · v2026.09.10

Supply & Ordering

Packaging
cylinders / ton drums / ISO tanks / tankers (by grade and order size)
Minimum order
confirmed on enquiry; negotiable for bulk purchases
Terms & lead time
FOB / CIF / EXW and others confirmed on request

Please confirm the exact packaging, minimum order and lead time via the enquiry form below.

Need a quote or technical documents for R123?

Get current pricing, packaging options, MSDS and compliance files. Send us your requirement and our sales and technical team will get back to you shortly.

Bulk orders, custom packaging and other technical questions are all welcome.

Ask Question About Product

Note: HTML is not translated!

Write a review

Note: HTML is not translated!
    Bad           Good

常见问题

R123 Refrigerant 50kg is a refrigerant/chemical product. It is widely used in refrigeration equipment such as refrigerators, freezers, water dispensers, automotive air conditioners, central air conditioning, dehumidifiers, cold storage and commercial refrigeration, as well as in aerosol propellants, blowing agents, fire-extinguishing and cleaning applications. See the product page for details.

Related Products

If the price of the product is reduced within 30 days, we will notify you via email, SMS and mobile client~
Notify you when the item is below the price
Mobile phone number
Email address
If the goods arrive within 30 days, we will notify you via email, SMS and mobile client~
Mobile phone number
Email address
Checkin successfully
Get bonus points:
My Points
Signed in Day
Checkin Record
Time Points Detailed description