This tool collects common fault codes for air conditioners from 38 major brands—including Gree, Midea, Haier, Aux, Daikin, Mitsubishi, Hitachi, Hisense, and TCL (378 codes indexed so far)—and supports searching by brand, fault code, or keyword to quickly view the code meaning and handling suggestions. The database is continuously expanded.
Usage tip: first select a brand, then enter the fault code (e.g., E1, P0, F4) or a keyword (e.g., “communication”, “sensor”, “high pressure”, “refrigerant leak”) to query.
Disclaimer: fault codes may differ across brands, series, and model years; please refer to the official service manual of the corresponding brand. Operations involving refrigerant, electricity, or disassembly carry safety risks—contact a qualified technician. Results from this tool are for reference only.
Air Conditioner Fault Code Reference
The following lists common fault codes for major air conditioner brands, with their meanings, possible causes and recommended actions. Compiled from commonly stable codes in public service manuals; refer to the official manual for your model. Code definitions vary by brand; for reference only.
Gree
| Code | Type | Fault Meaning | Possible Cause | Recommended Action | Repair Level |
|---|---|---|---|---|---|
E0 | Current Overload | Whole-unit AC voltage drop causing frequency derating | Unstable supply voltage | Check the supply voltage and use a voltage stabilizer | User can self-check |
E1 | Pressure Protection | System high-pressure protection | Dirty or blocked outdoor condenser, non-running fan, excess refrigerant, or refrigerant line blockage | Clean the outdoor unit's heat dissipation path and inspect the fan capacitor/motor | Professional repair required |
E2 | Defrost / Anti-freeze | Indoor freeze-prevention protection | Clogged filter, insufficient airflow, low refrigerant charge, or faulty electronic expansion valve | Clean the filter and run the fan at high speed to defrost; if the issue persists, check the sensor | Professional repair required |
E3 | Pressure Protection | System low-pressure protection | Refrigerant leak, line blockage, or faulty low-pressure switch | Perform a leak check, recharge refrigerant, and inspect the low-pressure switch | Professional repair required |
E4 | Pressure Protection | Compressor discharge temperature too high | Severe low refrigerant charge, dirty condenser, or compressor aging | Clean the outdoor unit, improve ventilation, and check the refrigerant level | Professional repair required |
E5 | Current Overload | Low-voltage overcurrent protection | Voltage fluctuation, compressor locked rotor, or faulty capacitor | Check the voltage and replace the start capacitor | Professional repair required |
E6 | Communication | Communication fault | Broken connection wire, loose connector, faulty main board, or signal interference | Check the indoor/outdoor wiring, re-seat the connectors, and replace the communication cable | Professional repair required |
E7 | Other | Reverse / missing phase protection | Incorrect power supply phase sequence | Check the power supply phase sequence | Professional repair required |
E8 | Defrost / Anti-freeze | High-temperature protection | Indoor temperature too high | Improve ventilation | User can self-check |
E9 | Other | Cold-air prevention protection | Indoor coil temperature too low | Wait for preheating to complete | User can self-check |
F0 | Pressure Protection | Refrigerant leak | Low refrigerant charge or system blockage | Perform a leak check and recharge refrigerant | Professional repair required |
F1 | Sensor | Room temperature sensor fault | Sensor open circuit / short circuit | Power off, check the sensor wiring, and replace with the same model sensor | User can self-check |
F2 | Sensor | Indoor coil sensor fault | Sensor open circuit / short circuit | Power off, check the sensor wiring, and replace with the same model sensor | User can self-check |
F3 | Sensor | Outdoor ambient temperature sensor fault | Sensor open circuit / short circuit | Power off, check the sensor wiring, and replace with the same model sensor | User can self-check |
F4 | Sensor | Outdoor condenser sensor fault | Sensor open circuit / short circuit | Power off, check the sensor wiring, and replace with the same model sensor | User can self-check |
F5 | Sensor | Outdoor discharge temperature sensor fault | Sensor open circuit / short circuit | Power off, check the sensor wiring, and replace with the same model sensor | User can self-check |
H1 | Defrost / Anti-freeze | Defrost (normal, not a fault) | Normal defrost during heating operation | Normal operation; recovers in about 10 minutes | User can self-check |
H3 | Current Overload | Compressor overload protection | Compressor overheating or excessive load | Check the compressor heat dissipation | Professional repair required |
H5 | Module | Inverter module protection | Poor module heat dissipation or high current | Clean the outdoor unit and check the module heat dissipation | Professional repair required |
C2 | Other | Earth leakage protection | Line leakage | Check the line insulation | User can self-check |
U7 | Other | Four-way valve abnormality | Four-way valve fault | Inspect and replace the four-way valve | Professional repair required |
Toshiba
| Code | Type | Fault Meaning | Possible Cause | Recommended Action | Repair Level |
|---|---|---|---|---|---|
E0 | Other | Indoor/outdoor EEPROM parameter fault | Main control board fault | Replace the main control board | Professional repair required |
E1 | Sensor | T1 sensor fault | Sensor fault | Replace the sensor | User can self-check |
E2 | Sensor | T2 sensor fault | Sensor fault | Replace the sensor | User can self-check |
E3 | Sensor | T3 sensor fault | Sensor fault | Replace the sensor | User can self-check |
E4 | Sensor | T4 sensor fault | Sensor fault | Replace the sensor | User can self-check |
E5 | Communication | Communication fault between main control board and display board | Communication abnormality | Check the communication line | User can self-check |
E7 | Current Overload | Outdoor fan stall fault | Outdoor fan stall | Inspect the outdoor fan | Professional repair required |
E8 | Communication | Indoor/outdoor communication fault | Communication abnormality | Check the communication line | User can self-check |
E9 | Other | Louver (air deflector) open/close fault | Louver open/close abnormality | Check the louver mechanism | Professional repair required |
Eb | Current Overload | Indoor DC fan stall | Indoor DC fan stall | Inspect the indoor fan | Professional repair required |
L0 | Defrost / Anti-freeze | Evaporator high/low temperature frequency limiting | Evaporator high/low temperature | Check the evaporator | User can self-check |
L1 | Defrost / Anti-freeze | Condenser high-temperature frequency limiting | Condenser high temperature | Check the condenser heat dissipation | User can self-check |
L2 | Pressure Protection | Compressor discharge high-temperature frequency limiting | Compressor discharge high temperature | Check the refrigerant level and improve heat dissipation | Professional repair required |
L3 | Current Overload | Current frequency limiting | Excessive current | Check the current | User can self-check |
P0 | Module | IPM module protection | IPM module fault | Check the module | Professional repair required |
P1 | Current Overload | Over/under voltage protection | Abnormal supply voltage | Check the voltage | User can self-check |
P2 | Module | Module temperature protection or system blockage protection | High module temperature or system blockage | Check the module and the system | Professional repair required |
P4 | Defrost / Anti-freeze | Indoor evaporator high/low temperature protection | Evaporator high/low temperature | Check the evaporator | User can self-check |
P5 | Defrost / Anti-freeze | Condenser high-temperature protection | Condenser high temperature | Check the condenser heat dissipation | User can self-check |
P7 | Pressure Protection | Outdoor discharge temperature too high | High discharge temperature | Check the refrigerant level and improve heat dissipation | Professional repair required |
Fujitsu
| Code | Type | Fault Meaning | Possible Cause | Recommended Action | Repair Level |
|---|---|---|---|---|---|
E0 | Current Overload | Whole-unit AC voltage drop causing frequency derating | Unstable supply voltage | Check the supply voltage and use a voltage stabilizer | User can self-check |
E1 | Pressure Protection | System high-pressure protection | Poor outdoor unit heat dissipation or excess refrigerant | Clean the outdoor unit and check the refrigerant level | Professional repair required |
E2 | Defrost / Anti-freeze | Indoor freeze-prevention protection | Dirty filter, insufficient airflow, or low refrigerant | Clean the filter and check the refrigerant | Professional repair required |
E3 | Pressure Protection | System low-pressure protection | Refrigerant leak | Perform a leak check and recharge refrigerant | Professional repair required |
E4 | Pressure Protection | Compressor discharge protection | High discharge temperature | Check the refrigerant level and improve heat dissipation | Professional repair required |
E5 | Current Overload | Low-voltage overcurrent protection | Voltage fluctuation | Check the voltage | User can self-check |
E6 | Communication | Communication fault | Broken connection wire or faulty main board | Check the wiring and inspect the main board | Professional repair required |
E7 | Other | Mode conflict | Inconsistent indoor and outdoor unit modes | Check the mode settings | User can self-check |
E8 | Defrost / Anti-freeze | High-temperature protection | Indoor temperature too high | Improve ventilation | User can self-check |
E9 | Other | Cold-air prevention protection | Indoor coil temperature too low | Wait for preheating | User can self-check |
F1 | Sensor | Indoor ambient temperature thermistor open/short circuit | Sensor fault | Replace the sensor | User can self-check |
F2 | Sensor | Indoor evaporator thermistor open/short circuit | Sensor fault | Replace the sensor | User can self-check |
F3 | Sensor | Outdoor ambient temperature thermistor open/short circuit | Sensor fault | Replace the sensor | User can self-check |
F4 | Sensor | Outdoor condenser thermistor open/short circuit | Sensor fault | Replace the sensor | User can self-check |
F5 | Sensor | Outdoor discharge thermistor open/short circuit | Sensor fault | Replace the sensor | User can self-check |
H1 | Defrost / Anti-freeze | Defrost | Defrost during heating operation | Normal operation; wait for recovery | User can self-check |
H3 | Current Overload | Compressor overload protection | Compressor overheating | Check the compressor heat dissipation | Professional repair required |
H5 | Module | Module protection | Poor module heat dissipation or high current | Clean the outdoor unit and check the module heat dissipation | Professional repair required |
H6 | Current Overload | No indoor fan motor feedback | Indoor fan motor fault | Inspect the indoor fan motor | Professional repair required |
C2 | Other | Earth leakage protection | Line leakage | Check the line insulation | User can self-check |
Common Questions About AC Fault Codes
If the air conditioner shows a fault code but does not cool or heat, what is the general cause?
A fault code is the result of the air conditioner's self-diagnosis; different codes correspond to different subsystems. Common areas: high/low pressure protection (excess or leaked refrigerant, dirty condenser), sensor faults (room/coil temperature probes), communication faults (indoor-outdoor wiring), and compressor/module protection (overheating or overcurrent). It is recommended to first record the complete code, then check it against the corresponding brand table below. For issues involving refrigerant, the compressor, or electrical circuits, do not dismantle the unit yourself.
What do codes like E1, E2, E3... mean in fault codes?
Each brand uses a different coding system, and there is no unified meaning of 'E1 = a certain fault.' For example, Gree E1 is system high-pressure protection, while Midea E1 is indoor-outdoor communication fault, and Haier E1 is room temperature sensor fault. Therefore, you must look up by the 'brand + code' combination; the table below is grouped by brand.
If high-pressure protection is displayed (often with E1/H1/pressure-related codes), can I handle it myself?
Partly. First power off and restart, clean the outdoor unit's condenser fins and clear any obstructions around it to ensure ventilation, and check whether the supply voltage is stable. If high pressure is still reported after cleaning and ventilation, or if it is accompanied by abnormal compressor noise or frequent shutdowns, it may indicate excess refrigerant, system blockage, or a compressor fault, and you should contact a professional technician (corresponding to 'Professional repair required' in the table).
How should sensor faults (mostly F-series, such as F1/F2/F3) be handled?
They are mostly caused by open circuit, short circuit, or resistance drift of the room/coil temperature probes. First power off and check whether the sensor plug is loose or the cable is damaged; if confirmed damaged, replace with the same model sensor (e.g., an NTC of about 10kΩ at 25℃). If the fault remains after replacement, it may be a problem with the main board detection circuit, and professional servicing is recommended.
Are 'defrost / cold-air prevention' codes such as H1, E9, and CH actual faults?
Usually not. During heating, the air conditioner defrosts periodically (about 10 minutes) and displays the relevant code; the cold-air prevention protection pauses the airflow when the indoor coil temperature is low, which is a normal protective function. Just wait for it to recover automatically. If it does not recover for a long time or is accompanied by other abnormalities, then troubleshoot it as a fault.
Under what circumstances must you contact professional repair rather than handle it yourself?
In the following situations, it is recommended to stop using the unit and contact after-sales service / professional repair: refrigerant leakage and recharging, compressor/inverter module protection, main board/module damage caused by abnormal supply voltage, and any situation requiring disassembly and live electrical operation. Codes marked 'Repair level = Professional repair required' in the table should not be handled by the user, to avoid electric shock or further damage.