R404A Refrigerant Bulk (Ton)

€7,812.00 Price drop reminder
  • Brand: Wula
  • Net Weight: 10 t
  • Chemical name R404A (R125/R143a/R134a blend)
  • Safety class A1
  • Availability: In Stock

Total €7,812.00

R404A refrigerant is used in refrigeration equipment such as cold storage, food refrigeration equipment, marine refrigeration equipment, industrial cryogenic refrigeration, commercial cryogenic refrigeration, transportation refrigeration equipment (refrigerated trucks, etc.), refrigeration condensation units, supermarket display cabinets and other refrigeration equipment. R404A is a replacement for newly installed refrigeration equipmentR22andR502The most common industry standard refrigerant (usually cryogenic refrigeration systems).

The R404A is closest to the operation of the R502 and is suitable for all environments where the R502 can operate normally. Since R404A is different from R502 and R22 in physical and chemical properties, theoretical cycle performance, and compressor oil, etc., for after-sales maintenance of refrigeration equipment initially installed with R502 and R22 refrigerants, if additional refrigerants need to be added or replaced, only R502 and R22 can be added, and usually R404A cannot be directly replaced. The R404A is suitable for new commercial refrigeration equipment, transportation refrigeration equipment or newer equipment at medium to low temperatures, can reach 15 ° F (-9.4 ° C) or colder, and is suitable for all environments where R502 can operate normally.

Composition of R404a:R125,R134A,R143A
Mole percentage: R125 accounts for 35.7817%, R134A accounts for 3.8264%, R143A accounts for 60.3919%
Mass percentage:R125accounting for 44%,R134Aaccounting for 4%,R143A52%

R404a Refrigerant Parameters

Name: R404A, HFC-404A Classification: Mixture, Mixed Refrigerants
Molecular weight: 97.6 Molar mass: 97.6g/mol
Critical temperature: 72℃ Critical pressure: 3.7MPa
Critical density: 0.4842g/cm3 Boiling point (101.3KPa): -46.1℃
CAS Number: 354-33-6/811-97-2/420-46-2 Liquid density (25℃):1.045g/cm3
Evaporation potential at boiling point KJ/Kg: 200.1 Specific heat (25℃) Kj/(kg.k): 1.54
Ozone Destruction Potential (ODP): 0 Global Warming Coefficient (GWP): 3922
Isobaric steam specific heat (30℃, 101.3kPa):0.21  

 

Product identity

R404A R404A (R125/R143a/R134a blend)
Safety class
A1
Type
HFC blend
GWP
3922 (IPCC AR4)
ODP
0 (not an ozone-depleting substance)

Application areas

Grouped by equipment type, for selection reference only; the equipment manufacturer's requirements and local regulations prevail.

Thermophysical properties

Normal boiling point (1 atm)
-46.5 °C
Saturation temp. (°C)-40-30-20-10020304045
Saturation pressure (bar abs)2.43.524.946.748.9214.518.523.426.2

Data taken from published pressure–temperature tables and interpolated; for selection reference only — do not use for safety-critical design, commissioning or charging calculations. The equipment manufacturer's requirements and primary references prevail. Refrigerant pressure–temperature tool

Alternatives & Matched Lubricant

Under the Kigali Amendment HFC phase-down, the following alternatives can be evaluated (R404A itself remains legal to use); the final selection must match the application, system pressure and lubricant compatibility.

Alternative refrigerants
R448A, R449A, R452A or R290/R744 low-temp solutions

Alternatives are a selection reference only; the equipment manufacturer's requirements and local regulations prevail.

GWP comparison: R404A vs. alternatives

Side-by-side comparison of R404A and its alternative refrigerants on the IPCC AR4 (GWP100) basis.

RefrigerantGWP100ODPSafety classChemical familyGWP change
R404A39220A1HFC blendBaseline
R448A13870A1HFO/HFC blend≈ -65%
R449A12820A1HFO/HFC blend≈ -67%
R452A21400A1HFO/HFC blend≈ -45%
R29030A3HC≈ -100%
R74410A1Natural refrigerant≈ -100%

GWP values are taken from this site's regulatory database (IPCC AR4 / GWP100); "GWP change" is an approximate figure calculated from the values above. Alternatives are a selection reference only; the equipment manufacturer's requirements and local regulations prevail.

Regulatory and compliance status (R404A / R404A (R125/R143a/R134a blend))

R404A (R404A (R125/R143a/R134a blend)) has an ODP of 0 and is not an ozone-depleting substance, and therefore is not bound by the Montreal Protocol phase-out schedule; but as a fluorinated greenhouse gas (F-gas, GWP 3922), it is controlled under the Kigali Amendment and the HFC reduction policies of major economies. The following are the regional status as of 2026, for reference in procurement and compliance decisions.

EU

  • RegulationF-gas Regulation (EU) 2024/573, in force since 2024-03-11
  • HFC quota60% in 2025–28, 30% in 2029–33, 20% in 2034–35, 15% from 2036; HFC fully phased out by 2050
  • New equipment restrictionsNew refrigeration/air-conditioning equipment with GWP>150 has been banned for sale in phases since 2022 (commercial refrigeration 2022, standalone equipment 2025, fully by 2030)
  • For R404AGWP 3922 > 150 — not permitted for new equipment of this type in the EU; servicing or top-up of existing equipment is unaffected

US

  • RegulationAmerican Innovation and Manufacturing (AIM) Act (in force since 2020-12-27)
  • TargetHFC production and consumption reduced by 85% by 2036
  • Quota cap60% in 2024–28, 30% in 2029–33, 20% in 2034–35, 15% from 2036
  • For R404ARegulated HFC, exchange value accounted by GWP 3922

China

  • RegulationKigali Amendment (entered into force for China on 2021-09-15)
  • Baseline2024 production/consumption freeze (production 18.53 billion tCO₂e, consumption 9.05 billion tCO₂e)
  • Reduction10% reduction by 2029, 30% by 2035, 50% by 2040, 80% by 2045
  • For R404AProduction and use are subject to quota management
  • Domestic procurement qualificationHFC-class refrigerants require environmental filing; see the Q&A below (system: new-ods.ozone.org.cn)

Japan

  • RegulationAct on Rational Use and Proper Management of Fluorocarbons
  • MechanismSets caps based on “weighted-average GWP” for designated products + compliance deadlines (not an all-sector ban)
  • Typical capsDomestic air conditioning ≤750 (2018), commercial air conditioning ≤750 (2020), automotive air conditioning ≤150 (2023), condensing/freezing units ≤1500 (2025), cold storage ≤100 (2019)
  • For R404AGWP 3922 exceeds condensing/refrigeration units (≤1500), residential air conditioners (≤750), commercial air conditioners (≤750), vehicle air conditioners (≤150), cold stores (≤100) — such new equipment must switch to a lower-GWP refrigerant
Other countries and regions (grouped by the Kigali Amendment)

Apart from the four columns of EU / US / China / Japan, the global 170+ Kigali parties all comply under the A5 (developing countries) / non-A5 (developed countries) groupings of the Montreal Protocol, and none impose equipment-level bans. The grouping determines the HFC reduction pace and is unrelated to geography — for example, the Middle East Gulf and India belong to A5 Group 2, while Brazil, Mexico and Chile belong to A5 Group 1 (same group as China). The table below is a quick reference for the groupings of major markets:

GroupingHFC reduction paceMajor countries / regions (representative)
A5 Group 1
(developing countries, including China)
2024 freeze → 10% reduction by 2029 → 30% by 2035 → 50% by 2040 → 80% by 2045Brazil, Argentina, Chile, Colombia, Peru, Mexico, South Africa, South Korea, Thailand, Indonesia, Malaysia, Vietnam, Egypt, Nigeria, etc. (about 140 countries in total)
A5 Group 2
(high-ambient-temperature group, HAT)
2028 freeze → 10% reduction by 2032 → 20% by 2037 → 30% by 2042 → 85% by 2047India, Bahrain, Iran, Iraq, Kuwait, Oman, Pakistan, Qatar, Saudi Arabia, United Arab Emirates
Other non-A5
(developed countries, except EU/US/Japan)
85% reduction by 2036 / reduced to 15% by 2050Canada, Australia, New Zealand, Switzerland, Norway, United Kingdom, Russia* (first two steps delayed: 5% by 2020, 35% by 2025), etc.

For R404A: subject to quota constraints, long-term supply restricted and prices trending upward. For the complete list of Parties and groupings, refer to the UNEP Ozone Secretariat (data version 2026.09).

Buyer conclusion: R404A is still legally produced, sold and used worldwide and is not subject to a comprehensive ban; but as a fluorinated greenhouse gas (GWP 3922), its supply is constrained by national quotas and prices trend upward in the long term. In the EU, new equipment with GWP>150 has been banned in stages; GWP 3922 exceeds that threshold, so it is not permitted for such new equipment; The US and China are also progressively reducing HFCs according to their own schedules; Japan promotes substitution for domestic/commercial/automotive air conditioning based on GWP caps. Recommendation: for new projects, prioritise evaluating low-GWP alternatives (R448A, R449A, R452A or R290/R744 low-temp solutions); existing equipment can continue to be maintained with R404A. Domestic customers must complete environmental filing (“Ozone-Depleting Substances Information Management System”) before purchasing, and suppliers must verify the filing and may not sell to individuals or enterprises not filed as required.

Supply & Ordering

Packaging
cylinders / ton drums / ISO tanks / tankers (by grade and order size)
Minimum order
confirmed on enquiry; negotiable for bulk purchases
Terms & lead time
FOB / CIF / EXW and others confirmed on request

Please confirm the exact packaging, minimum order and lead time via the enquiry form below.

About WULA

WULA was founded in 2013. We are a refrigerant supply organizer, focused on moving goods from the production line to the customer's own line and site.

Compliance paperwork
We help customers meet compliance requirements: sales filing, per-transaction verification, quarterly reporting and three-year retention of documents.
Order handling
Scattered orders are managed through consolidated, data-driven administration to keep procurement efficient.
Supply allocation
Forecasting and coordinated allocation across multiple warehouses, to keep supply stable.

Need a quote or technical documents for R404A?

Get current pricing, packaging options, MSDS and compliance files. Send us your requirement and our sales and technical team will get back to you shortly.

Bulk orders, custom packaging and other technical questions are all welcome.

Regulatory data updated: 2026-09-18 · v2026.09.12

Ask Question About Product

Note: HTML is not translated!

Write a review

Note: HTML is not translated!
    Bad           Good

常见问题

R404A Refrigerant Bulk (Ton) is a refrigerant/chemical product. It is widely used in refrigeration equipment such as refrigerators, freezers, water dispensers, automotive air conditioners, central air conditioning, dehumidifiers, cold storage and commercial refrigeration, as well as in aerosol propellants, blowing agents, fire-extinguishing and cleaning applications. See the product page for details.

Related Products

Juhua R404A 9.5kg
If the price of the product is reduced within 30 days, we will notify you via email, SMS and mobile client~
Notify you when the item is below the price
Mobile phone number
Email address
If the goods arrive within 30 days, we will notify you via email, SMS and mobile client~
Mobile phone number
Email address
Checkin successfully
Get bonus points:
My Points
Signed in Day
Checkin Record
Time Points Detailed description