R13 refrigerant is also alias R-13, Freon 13, F13, F-13, CFC13, CFC-13, trifluorochloromethane. The trade names include Freon 13, etc., the Chinese name trifluoro-chloromethane, the English name Chlorotrifluoromethane, and the chemical formula CClF3. Since R13 belongs to the CFC class (the first batch of restricted ODS substances, Class I Ozone-deploying Substances), which is harmful to the ozone layer and has a greenhouse effect, in developed and some developing countries, initial installation on new refrigeration equipment or re-addition on old equipment has been stopped; China stopped the production of R13 refrigerant and initial installation on new refrigeration and air-conditioning equipment in 2007.
As a widely used cryogenic refrigerant, R13 is mainly used in cryogenic equipment such as ultra-low temperature refrigerators or freezers, blood bank refrigerators, freezers/freeze dryers, environmental test chambers/equipment (cold and hot shock testers), biochemical test chambers, etc.(including scientific refrigeration, medical refrigeration, etc.), and is mostly used in the low temperature section of these cascade refrigeration systems. Trifluoro-monochloromethane can also be used as a fire extinguishing agent. withR22The composed refrigeration system is used for ultra-low temperature refrigeration devices at-80~-120℃. It is also used as a blowing agent in foam plastics.
R13 Refrigerant Physical Property Parameters
| Abbreviations: R13, CFC-13, f13, Freon-13, Refrigerant-13 | Chinese name: trifluorochloromethane; Freon-13; trifluorochloromethane |
| English full name: chlorotrifluoromethane | CAS Number: 75-72-9 |
| Molecular Formula: CClF3 | Classification: Pure matter |
| Molecular weight: 104.459 | Molar mass: 104.459g/mol |
| Critical temperature: 28.85℃ | Critical pressure: 3.879MPa (absolute pressure) |
| Critical density: 582.88122kg/m3 | Latent heat of evaporation (at boiling point, 1atm), kJ/kg: 150.1 |
| Density:(-130℃)1.703g/cm3 | Standard boiling point: -81.48℃ |
| Triple point temperature: -181.15℃ | Eccentricity factor: 0.1723kJ (kg*℃) |
| Dipole moment: 0.51D (Debye) | Melting point: -182℃ |
| Solubility (atmospheric pressure, 25℃),%(mass): 0.009 | Risk factor: 2.2 |
| Ozone Depleting Potential (ODP): 1.0 | Global Warming Potential (GWP): 14400 |
R13 Refrigerant Quality Indicator
level superior grade
Purity, %(mass), ≥ 99.5
Moisture, mg/kg,≤ 20
Acidity, %(mass), ≤ 0.0001
Evaporation residue, %(mass) ,≤ 0.01
Non-condensable gas in gas phase,%(volume), ≤ 1.5
R13 Packaging Specifications
Reusable high-pressure steel cylinder packaging (need to recycle packaging steel cylinders): 6kg/bottle, 35kg/bottle.
R13 Storage and transportation
R13 refrigerant cylinders are high-pressure containers. When stored, they should be kept away from fire, heat sources, and avoid direct exposure to the sun. They should be stored in a cool, dry and ventilated warehouse; they should be loaded and unloaded lightly during handling to prevent cylinders, valves and other accessories from being damaged.
Product identity
- Safety class
- A1
- Type
- CFC
- GWP
- 14400 (IPCC AR4)
- ODP
- 1.0 (ozone-depleting substance, controlled under the Montreal Protocol)
Application areas
Grouped by equipment type, for selection reference only; the equipment manufacturer's requirements and local regulations prevail.
Thermophysical properties
- Normal boiling point (1 atm)
- -81.4 °C
| Saturation temp. (°C) | -121.4 | -101.4 | -91.4 | -81.4 | -61.4 | -41.4 | -31.4 | -21.4 | -1.4 | 18.6 | 28.6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Saturation pressure (bar abs) | 0.0618 | 0.3016 | 0.5742 | 1.0132 | 2.6382 | 5.7376 | 8.0387 | 10.9551 | 19.0126 | 30.8118 | 38.5841 |
Data taken from published pressure–temperature tables and interpolated; for selection reference only — do not use for safety-critical design, commissioning or charging calculations. The equipment manufacturer's requirements and primary references prevail. Refrigerant pressure–temperature tool
Regulatory and compliance status (R13 / Chlorotrifluoromethane (CFC-13)) — fully phased out
R13 (Chlorotrifluoromethane (CFC-13)) belongs to the chlorofluorocarbons (CFC), with an ODP of 1.0, and is a Class I controlled substance under the Montreal Protocol. Production and consumption have been fully halted worldwide, with presence only in very few exempted uses (e.g. essential-use exemptions, feedstock uses) and in the recovery and reclamation sector. The following are the regional status as of 2026.
EU
- RegulationOzone-Depleting Substances Regulation (EC) 1005/2009
- StatusProduction, placing on the market and use fully prohibited
- ExemptionsOnly essential uses (e.g. metered-dose inhalers), feedstock and laboratory uses may apply for exemption
- For R13Not permitted for new installations or servicing top-up; equipment must be retrofitted or replaced with alternative refrigerants
US
- RegulationClean Air Act Title VI + SNAP program
- StatusClass I substance, production and import halted since 1996
- Existing stockOnly reclaimed refrigerant is permitted for the maintenance of existing stock equipment
- For R13Only reclaimed product may be used for existing equipment; no new production/import permitted
China
- RegulationRegulations on the Administration of Ozone-Depleting Substances (2024 revision)
- StatusCFC class fully phased out; production and use prohibited
- Existing stockReclaimed refrigerant may circulate within the filing and registration system
- For R13No legal supply of virgin product; equipment must be retrofitted or decommissioned
Japan
- RegulationOzone Layer Protection Act + Act on Rational Use and Proper Management of Fluorocarbons
- StatusSpecific fluorocarbons (CFC) fully abolished
- Existing stockReclaimed refrigerant limited to existing equipment
- For R13No supply of virgin product; must be retrofitted or replaced
Other countries and regions (grouped by the Kigali Amendment)
Apart from the four columns of EU / US / China / Japan, the global 170+ Kigali parties all comply under the A5 (developing countries) / non-A5 (developed countries) groupings of the Montreal Protocol, and none impose equipment-level bans. The grouping determines the HFC reduction pace and is unrelated to geography — for example, the Middle East Gulf and India belong to A5 Group 2, while Brazil, Mexico and Chile belong to A5 Group 1 (same group as China). The table below is a quick reference for the groupings of major markets:
| Grouping | HFC reduction pace | Major countries / regions (representative) |
|---|---|---|
| A5 Group 1 (developing countries, including China) | 2024 freeze → 10% reduction by 2029 → 30% by 2035 → 50% by 2040 → 80% by 2045 | Brazil, Argentina, Chile, Colombia, Peru, Mexico, South Africa, South Korea, Thailand, Indonesia, Malaysia, Vietnam, Egypt, Nigeria, etc. (about 140 countries in total) |
| A5 Group 2 (high-ambient-temperature group, HAT) | 2028 freeze → 10% reduction by 2032 → 20% by 2037 → 30% by 2042 → 85% by 2047 | India, Bahrain, Iran, Iraq, Kuwait, Oman, Pakistan, Qatar, Saudi Arabia, United Arab Emirates |
| Other non-A5 (developed countries, except EU/US/Japan) | 85% reduction by 2036 / reduced to 15% by 2050 | Canada, Australia, New Zealand, Switzerland, Norway, United Kingdom, Russia* (first two steps delayed: 5% by 2020, 35% by 2025), etc. |
For R13: globally phased out, no legal supply of virgin product. For the complete list of Parties and groupings, refer to the UNEP Ozone Secretariat (data version 2026.09).
Supply & Ordering
- Packaging
- cylinders / ton drums / ISO tanks / tankers (by grade and order size)
- Minimum order
- confirmed on enquiry; negotiable for bulk purchases
- Terms & lead time
- FOB / CIF / EXW and others confirmed on request
Please confirm the exact packaging, minimum order and lead time via the enquiry form below.
About WULA
WULA was founded in 2013. We are a refrigerant supply organizer, focused on moving goods from the production line to the customer's own line and site.
- Compliance paperwork
- We help customers meet compliance requirements: sales filing, per-transaction verification, quarterly reporting and three-year retention of documents.
- Order handling
- Scattered orders are managed through consolidated, data-driven administration to keep procurement efficient.
- Supply allocation
- Forecasting and coordinated allocation across multiple warehouses, to keep supply stable.
Need a quote or technical documents for R13?
Get current pricing, packaging options, MSDS and compliance files. Send us your requirement and our sales and technical team will get back to you shortly.
Bulk orders, custom packaging and other technical questions are all welcome.
Regulatory data updated: 2026-09-18 · v2026.09.12