R115 Refrigerant

€175.00 Price drop reminder
  • Brand: Wula
  • Net Weight: 10 kg
  • Chemical name Chloropentafluoroethane (CFC-115)
  • Safety class A1
  • Availability: 无货

Total €175.00
R115(pentafluorochloroethane) is used as a refrigerant, sol propellant, insulating gas, and etchant in the food industry. Used to prepare medium and low temperature cooling medium R502, etc.

R115 Refrigerant Parameters
Name: R115, Freon 115, CFC-115 Chinese name: pentafluorochloroethane; chloropentafluoroethane
English full name: chloropentafluoroethane Chemical molecular formula: CClF2CF3
Molecular weight:155 Standard boiling point: -39℃
Critical temperature:80℃ Critical pressure: 3.13MPa (absolute pressure)
Critical density:615kg/m3 CAS Number: 76-15-3
Relative density (water =1):1.3g/cm3 (20℃) Relative density (air =1)5.6

Product identity

R115 Chloropentafluoroethane (CFC-115)
Safety class
A1
Type
CFC
GWP
7370 (IPCC AR4)
ODP
0.6 (ozone-depleting substance, controlled under the Montreal Protocol)

Application areas

Grouped by equipment type, for selection reference only; the equipment manufacturer's requirements and local regulations prevail.

Thermophysical properties

Normal boiling point (1 atm)
-39.2 °C
Saturation temp. (°C)-79.2-69.2-49.2-39.2-29.2-19.20.810.820.840.850.8
Saturation pressure (bar abs)0.10910.20980.63311.01331.55142.28664.51866.10758.077613.382416.8458

Data taken from published pressure–temperature tables and interpolated; for selection reference only — do not use for safety-critical design, commissioning or charging calculations. The equipment manufacturer's requirements and primary references prevail. Refrigerant pressure–temperature tool

Regulatory and compliance status (R115 / Chloropentafluoroethane (CFC-115)) — fully phased out

R115 (Chloropentafluoroethane (CFC-115)) belongs to the chlorofluorocarbons (CFC), with an ODP of 0.6, and is a Class I controlled substance under the Montreal Protocol. Production and consumption have been fully halted worldwide, with presence only in very few exempted uses (e.g. essential-use exemptions, feedstock uses) and in the recovery and reclamation sector. The following are the regional status as of 2026.

EU

  • RegulationOzone-Depleting Substances Regulation (EC) 1005/2009
  • StatusProduction, placing on the market and use fully prohibited
  • ExemptionsOnly essential uses (e.g. metered-dose inhalers), feedstock and laboratory uses may apply for exemption
  • For R115Not permitted for new installations or servicing top-up; equipment must be retrofitted or replaced with alternative refrigerants

US

  • RegulationClean Air Act Title VI + SNAP program
  • StatusClass I substance, production and import halted since 1996
  • Existing stockOnly reclaimed refrigerant is permitted for the maintenance of existing stock equipment
  • For R115Only reclaimed product may be used for existing equipment; no new production/import permitted

China

  • RegulationRegulations on the Administration of Ozone-Depleting Substances (2024 revision)
  • StatusCFC class fully phased out; production and use prohibited
  • Existing stockReclaimed refrigerant may circulate within the filing and registration system
  • For R115No legal supply of virgin product; equipment must be retrofitted or decommissioned

Japan

  • RegulationOzone Layer Protection Act + Act on Rational Use and Proper Management of Fluorocarbons
  • StatusSpecific fluorocarbons (CFC) fully abolished
  • Existing stockReclaimed refrigerant limited to existing equipment
  • For R115No supply of virgin product; must be retrofitted or replaced
Other countries and regions (grouped by the Kigali Amendment)

Apart from the four columns of EU / US / China / Japan, the global 170+ Kigali parties all comply under the A5 (developing countries) / non-A5 (developed countries) groupings of the Montreal Protocol, and none impose equipment-level bans. The grouping determines the HFC reduction pace and is unrelated to geography — for example, the Middle East Gulf and India belong to A5 Group 2, while Brazil, Mexico and Chile belong to A5 Group 1 (same group as China). The table below is a quick reference for the groupings of major markets:

GroupingHFC reduction paceMajor countries / regions (representative)
A5 Group 1
(developing countries, including China)
2024 freeze → 10% reduction by 2029 → 30% by 2035 → 50% by 2040 → 80% by 2045Brazil, Argentina, Chile, Colombia, Peru, Mexico, South Africa, South Korea, Thailand, Indonesia, Malaysia, Vietnam, Egypt, Nigeria, etc. (about 140 countries in total)
A5 Group 2
(high-ambient-temperature group, HAT)
2028 freeze → 10% reduction by 2032 → 20% by 2037 → 30% by 2042 → 85% by 2047India, Bahrain, Iran, Iraq, Kuwait, Oman, Pakistan, Qatar, Saudi Arabia, United Arab Emirates
Other non-A5
(developed countries, except EU/US/Japan)
85% reduction by 2036 / reduced to 15% by 2050Canada, Australia, New Zealand, Switzerland, Norway, United Kingdom, Russia* (first two steps delayed: 5% by 2020, 35% by 2025), etc.

For R115: globally phased out, no legal supply of virgin product. For the complete list of Parties and groupings, refer to the UNEP Ozone Secretariat (data version 2026.09).

Buyer conclusion: R115 is a CFC-class controlled substance with an ODP of 0.6, and production and consumption have been halted worldwide; no legal supply of virgin product exists. Any product circulating on the market can only be reclaimed refrigerant (subject to local reclamation standards and filing requirements), and must not be used in new equipment. If your equipment is still using R115, it is recommended to assess a retrofit to an alternative (R32, R454B, R513A or a hydrocarbon refrigerant) as soon as possible — the retrofit involves re-matching the compressor lubricant, seals and charge quantity; please contact a professional service provider. Procurement note: any source claiming to supply “brand-new virgin R115” carries compliance risk.

Supply & Ordering

Packaging
cylinders / ton drums / ISO tanks / tankers (by grade and order size)
Minimum order
confirmed on enquiry; negotiable for bulk purchases
Terms & lead time
FOB / CIF / EXW and others confirmed on request

Please confirm the exact packaging, minimum order and lead time via the enquiry form below.

About WULA

WULA was founded in 2013. We are a refrigerant supply organizer, focused on moving goods from the production line to the customer's own line and site.

Compliance paperwork
We help customers meet compliance requirements: sales filing, per-transaction verification, quarterly reporting and three-year retention of documents.
Order handling
Scattered orders are managed through consolidated, data-driven administration to keep procurement efficient.
Supply allocation
Forecasting and coordinated allocation across multiple warehouses, to keep supply stable.

Need a quote or technical documents for R115?

Get current pricing, packaging options, MSDS and compliance files. Send us your requirement and our sales and technical team will get back to you shortly.

Bulk orders, custom packaging and other technical questions are all welcome.

Regulatory data updated: 2026-09-18 · v2026.09.12

Ask Question About Product

Note: HTML is not translated!

Write a review

Note: HTML is not translated!
    Bad           Good

常见问题

R115 Refrigerant is a refrigerant/chemical product. It is widely used in refrigeration equipment such as refrigerators, freezers, water dispensers, automotive air conditioners, central air conditioning, dehumidifiers, cold storage and commercial refrigeration, as well as in aerosol propellants, blowing agents, fire-extinguishing and cleaning applications. See the product page for details.

Related Products

R114 Refrigerant

R114 Refrigerant

€343.00
If the price of the product is reduced within 30 days, we will notify you via email, SMS and mobile client~
Notify you when the item is below the price
Mobile phone number
Email address
If the goods arrive within 30 days, we will notify you via email, SMS and mobile client~
Mobile phone number
Email address
Checkin successfully
Get bonus points:
My Points
Signed in Day
Checkin Record
Time Points Detailed description