1 Identification
1.1 Product identifier
| Chemical name | Propylene (Propene) |
|---|---|
| Common names / synonyms | R1270, HC-1270, Propene, Methylethylene, 1-Propene |
| CAS number | 115-07-1 |
| UN number | 1077 (Propylene, flammable gas) |
| Dangerous goods code | Class 2.1 Flammable gas |
| Molecular formula | C3H6 (CH2=CHCH3) |
| Molecular weight | 42.08 g/mol |
| Recommended use | Refrigerant (commercial/industrial refrigeration), chemical feedstock (polypropylene, propylene oxide, acrylonitrile production), fuel, welding/cutting gas |
1.2 Details of the supplier of the safety data sheet
| Supplier name | Hangzhou Wula Chemical Co., Ltd. |
|---|---|
| Address | No. 7 Longtan Road, Yuhang District, Hangzhou, Zhejiang Province, China |
| Postal code | 311100 |
| Telephone | +86-571-87024025 |
| Fax | +86-571-87024025 |
| safety@wulachem.cn |
1.3 Emergency telephone number
National Chemical Emergency Hotline (China): +86-532-83889090 (24 hours)
Supplier Emergency Contact: +86-571-87024025
2 Hazards identification
2.1 GHS classification
- Flammable gas (Physical hazard) — Category 1A (extremely flammable)
- Compressed gas (Physical hazard) — Liquefied gas
- Specific target organ toxicity - single exposure (Health hazard, narcotic effect) — Category 3
- Carcinogenicity (Health hazard) — Category 1B (under high-concentration long-term exposure conditions)
- Hazardous to the aquatic environment - Acute (Environmental hazard) — Category 1
Note: The carcinogenicity classification (H350) is based on animal study evidence of kidney tumors from high-concentration (≥6,000 ppm) lifelong exposure. Propylene is metabolized in vivo to propylene oxide (a Category 2 carcinogen), which is the carcinogenic mechanism. Under normal occupational exposure conditions (below TLV), carcinogenic risk is not significant.
2.2 GHS label elements
Signal word: Danger
Hazard statements:
- H220 Extremely flammable gas.
- H280 Contains gas under pressure; may explode if heated.
- H336 May cause drowsiness or dizziness.
- H350 May cause cancer (under high-concentration long-term exposure conditions).
- H400 Very toxic to aquatic life.
Precautionary statements:
- P101 If medical advice is needed, have product container or label at hand.
- P102 Keep out of reach of children.
- P201 Obtain special instructions before use.
- P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P271 Use only outdoors or in a well-ventilated area.
- P308+P313 If exposed or concerned: Get medical advice/attention.
- P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
- P381 In case of leakage, eliminate all ignition sources.
- P391 Collect spillage.
- P403 Store in a well-ventilated place.
- P410+P403 Protect from sunlight. Store in a well-ventilated place.
- P405 Store locked up.
- P501 Dispose of contents/container in accordance with local regulations.
2.3 Other hazards
- This is an A3 flammability class refrigerant (ASHRAE safety group) with an extremely wide explosive range (2.0%~11.1%), very low flash point (-108°C). Even a small leak can form an explosive gas mixture.
- Vapor is heavier than air (vapor density ~1.45 times air) and can spread long distances along the ground; ignition can flash back to the source.
- Refrigerant-grade propylene is not odorized; leaks cannot be detected by smell. Combustible gas detectors are mandatory.
- High concentrations can cause asphyxiation and central nervous system depression (dizziness, drowsiness, loss of consciousness).
- Liquid contact with skin or eyes can cause severe frostbite.
- High-concentration long-term exposure poses carcinogenic risk (IARC Group 2B). Propylene is metabolized to propylene oxide, a direct-acting genotoxic carcinogen.
- Cylinders heated by fire may undergo BLEVE (Boiling Liquid Expanding Vapor Explosion).
- Propylene is an alkene (contains C=C double bond), making it chemically more reactive than alkanes (e.g., propane, isobutane).
3 Composition/information on ingredients
3.1 Substance/mixture
This product is a pure substance.
3.2 Composition information
| Component name | CAS No. | Concentration (by mass) |
|---|---|---|
| Propylene | 115-07-1 | ≥99.5% (refrigerant grade) |
3.3 Impurity information
| Impurity | Specification limit |
|---|---|
| Moisture | ≤10 ppm |
| Acidity (as HCl) | ≤1 ppm |
| Evaporation residue | ≤100 ppm |
| Non-condensable gas (25°C, vol%) | ≤1.5% |
| Sulfides | ≤1 ppm |
| Other hydrocarbons (propane, ethane, etc.) | ≤0.5% |
| Methylacetylene (propyne) | ≤5 ppm (safety limit to prevent polymerization) |
Note: Propylene is an unsaturated alkene and is chemically more reactive than alkanes. Refrigerant-grade propylene must strictly control alkyne impurity content (e.g., methylacetylene) to prevent polymerization under specific conditions.
4 First aid measures
4.1 Description of necessary first aid measures
General advice: Remove victim from contaminated area immediately. Keep warm and at rest. Show this SDS to attending physician. Note: Ensure no explosion hazard before entering the leak area.
Inhalation:
- Move victim to fresh air immediately. Keep airway clear.
- Administer oxygen if breathing is difficult.
- If not breathing, give artificial respiration (preferably with bag-valve-mask; avoid mouth-to-mouth).
- If no pulse, start cardiopulmonary resuscitation (CPR) immediately.
- Keep victim warm and at rest. Monitor condition closely.
- Seek medical attention immediately. Inform physician of possible carcinogen exposure.
Skin contact (frostbite):
- Immediately flush affected area with large amounts of lukewarm water (37–40°C) to promote rewarming.
- Do NOT use hot water (>40°C) or direct heat (e.g., electric heaters).
- Do NOT rub or massage frostbitten area; this may worsen tissue damage.
- Carefully remove frozen clothing. If clothing sticks to skin, do NOT pull it off; cut around it.
- Cover with sterile dressing.
- Seek medical attention immediately.
Eye contact:
- Immediately hold eyelids open and rinse thoroughly with plenty of water or normal saline for at least 15 minutes.
- Ensure complete irrigation of all eye surfaces by lifting upper and lower lids.
- Remove contact lenses if present and easily removable.
- Seek medical attention immediately, preferably from an ophthalmologist.
Ingestion:
This substance is a gas at ambient temperature; ingestion is highly unlikely. If liquid propylene is accidentally swallowed (extremely rare), do NOT induce vomiting; seek medical attention immediately.
4.2 Most important symptoms and effects, both acute and delayed
- Acute inhalation: dizziness, drowsiness, headache, nausea, ataxia, loss of consciousness, cardiac arrhythmia; high concentrations may cause asphyxiation.
- Skin contact (liquid): frostbite (pale, hard skin, pain, blistering).
- Eye contact (liquid): severe frostbite, corneal damage, visual impairment.
- Long-term high-concentration exposure: carcinogenic risk (kidney tumors). Propylene metabolite propylene oxide is genotoxic.
4.3 Indication of any immediate medical attention and special treatment needed
- Symptomatic and supportive therapy. Maintain airway; administer oxygen if needed.
- Monitor cardiac function; high-concentration exposure may cause arrhythmias.
- Treat frostbite with standard protocols: lukewarm water (37–40°C) rewarming. Do NOT use dry heat or massage.
- Patients with long-term high-concentration exposure should undergo kidney function tests and regular medical examinations.
- Inform patient of propylene's carcinogenic risk (IARC Group 2B); recommend long-term health follow-up.
5 Firefighting measures
5.1 Extinguishing media
Suitable extinguishing media: Dry chemical powder, carbon dioxide, water fog (for cooling containers). For large gas fires, the preferred approach is to shut off the gas source and then extinguish.
Unsuitable extinguishing media: Direct water jets (may spread the flame and expand the hazard area; direct spray onto liquid propylene tanks may cause splashing).
5.2 Special hazards arising from the substance or mixture
- Extremely flammable; forms explosive mixtures with air (explosive range 2.0%~11.1%, very high upper limit).
- Vapor is heavier than air and can travel along the ground to remote ignition sources, causing flash-back.
- Cylinders or tanks exposed to heat may undergo BLEVE (Boiling Liquid Expanding Vapor Explosion), producing shock waves and flying fragments.
- Incomplete combustion produces carbon monoxide (CO), a toxic gas.
- Burning in confined spaces may cause vapor explosion.
- Combustion smoke may contain irritating organic compounds.
5.3 Hazardous combustion products
Carbon dioxide (CO₂), water (H₂O), carbon monoxide (CO, from incomplete combustion), trace aldehydes and organic peroxides
5.4 Advice for firefighters
- Firefighters must wear positive-pressure self-contained breathing apparatus (SCBA) and full protective fire-resistant clothing.
- For leaking gas fire: Do NOT extinguish the flame unless the leak can be safely stopped. Continued burning prevents gas accumulation and potential larger-scale vapor cloud explosion. The flame will self-extinguish when the leak is stopped.
- If possible, move containers from fire area to a safe location.
- Cool containers with water spray from a safe distance until fire is extinguished.
- Immediately evacuate if containers show discoloration or if pressure relief devices begin to vent.
- Isolate the area; keep unauthorized personnel out.
- Apply large quantities of water from a distance to cool fire-exposed containers. Personnel must stay upwind.
6 Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
- Evacuate personnel from the leak area to upwind locations immediately. Establish a perimeter and restrict access.
- Immediately eliminate all ignition sources: cut power, prohibit open flames, no smoking, prohibit use of non-explosion-proof electrical equipment.
- Emergency responders should wear SCBA, anti-static work clothing, cryogenic gloves, and eye protection.
- Enter from upwind direction.
- Stop leak if it can be done safely. If the valve cannot be closed, retreat to a safe distance and await professional assistance.
- Do not touch or walk through spilled material.
- Use only non-sparking tools.
6.2 Environmental precautions
- Prevent gas from entering sewers, basements, cable trenches, or confined spaces (highly likely to accumulate and cause explosion).
- Ventilate the area to accelerate dispersion.
- Avoid release to waterways and soil.
- Vapor is heavier than air and accumulates in low-lying areas. Monitor combustible gas concentration (LEL).
6.3 Methods and materials for containment and cleaning up
- Small leak: Increase ventilation to accelerate gas dispersion. Use combustible gas detectors to monitor concentration, ensuring it is below the lower explosive limit (LEL = 2.0%).
- Large leak:
- Immediately establish a security perimeter and evacuate downwind personnel.
- Close source valve if safe to do so.
- Use dedicated gas recovery equipment or flare system for safe disposal.
- If recovery is not possible, ignite and burn the gas at a safe location (under professional guidance only) to prevent accumulation and explosion.
- Use water fog/mist to dilute vapor, but do NOT direct water spray at the leak point.
- Cylinder leak: Move cylinder to a well-ventilated safe area and vent slowly. If valve cannot be closed, monitor from a safe distance and contact supplier for professional handling.
6.4 Reference
See Section 8 (Exposure controls/personal protection) and Section 13 (Disposal considerations).
7 Handling and storage
7.1 Precautions for safe handling
- Handle in closed systems with adequate natural ventilation or local exhaust.
- Personnel must be specially trained and strictly follow operating procedures. Certified personnel only.
- Prevent gas leakage into workplace atmosphere.
- All equipment, piping, and cylinders must be reliably grounded to prevent static accumulation. Grounding resistance must meet anti-static requirements.
- Prohibit use of spark-producing mechanical equipment and tools (use non-sparking copper alloy tools).
- No smoking, eating, or drinking in work areas.
- Handle cylinders carefully; do not drop, slide, roll, or bump cylinders.
- Wear insulated gloves and eye/face protection when handling liquid to prevent frostbite.
- Equip area with combustible gas detection/alarm system and leak emergency response equipment.
- Periodically inspect cylinders, valves, and piping for leaks using leak detection solution or combustible gas detectors.
- Control workplace propylene concentration below occupational exposure limits to minimize long-term exposure.
- Propylene is an alkene; avoid contact with polymerization catalysts (e.g., Ziegler-Natta catalysts).
7.2 Conditions for safe storage, including any incompatibilities
- Store in a cool, dry, well-ventilated flammable gas warehouse. The warehouse must comply with GB 50016 (fire protection design code) for Class A warehouse requirements.
- Storage temperature should not exceed 30°C. Keep away from fire, heat sources, and direct sunlight.
- Store separately from oxidizers, halogens, strong acids, strong bases, and polymerization catalysts. Do not co-store with incompatible materials.
- Storage area should be equipped with leak emergency response equipment and combustible gas detectors.
- Cylinders must be stored upright with valve caps and safety rings in place, properly secured to prevent falling.
- Use explosion-proof lighting and ventilation systems. Switches and receptacles must be located outside the warehouse or be of explosion-proof type.
- Prohibit use of equipment and tools that can generate sparks.
- Filling coefficient must not exceed 0.43 kg/L (propylene).
- Post clear safety warning signs: "No Smoking," "Flammable Gas," and "May Cause Cancer."
- Storage areas must be kept at a safe distance from residential areas, schools, hospitals, and other populated areas.
- Implement two-person receiving/issuing and two-person custody system.
7.3 Specific end uses
When used as a refrigerant, only trained and certified technicians may handle the product. Refrigeration system design, installation, and maintenance must comply with GB 9237. R1270 refrigeration systems should minimize charge quantity, use sealed designs, and be equipped with combustible gas detection. Personnel with long-term propylene exposure should undergo periodic occupational health examinations (including kidney function tests). Do not use for direct food contact, medical inhalation, or other unapproved applications.
8 Exposure controls/personal protection
8.1 Control parameters
| China OEL (Occupational Exposure Limit) | No established legal limit. Maintain oxygen content ≥19.5% in air. |
|---|---|
| ACGIH TLV-TWA (USA) | 500 ppm (approx. 860 mg/m³), 8-hour time-weighted average (ACGIH A3 carcinogen) |
| NIOSH REL-TWA (USA) | No specific limit established |
| OSHA PEL-TWA (USA) | No specific limit established |
| Carcinogenicity classification | IARC Group 2B (Possibly carcinogenic to humans); ACGIH A3 (Confirmed animal carcinogen with unknown relevance to humans) |
| Biological limit value | Not established |
Note: Propylene's carcinogenicity is based on animal study evidence of kidney tumors from very high-concentration (6,000~12,000 ppm) lifelong exposure. Under normal occupational exposure conditions (below TLV), carcinogenic risk is not significant. Minimizing exposure is recommended.
8.2 Exposure monitoring methods
Gas chromatography with flame ionization detection (GC-FID) or mass spectrometry (GC-MS); combustible gas detectors (LEL monitoring, catalytic combustion or infrared type); photoionization detector (PID).
8.3 Appropriate engineering controls
- Enclosed process design with general ventilation or local exhaust.
- Provide safety shower and eyewash station.
- Install combustible gas detection alarms (audible and visual) in areas where leaks may occur. Alarm set point ≤20% LEL.
- All electrical equipment, lighting, and ventilation must be explosion-proof (complying with GB 3836).
- All metal equipment, piping, and cylinders must be reliably grounded. Grounding resistance <10Ω.
- Workplace floors must be made of non-sparking materials.
- For positions with long-term propylene exposure, personal sampling pumps should be provided for exposure assessment.
8.4 Individual protection measures
Respiratory protection:
- Normal conditions (below exposure limit and normal oxygen): no special protection required.
- Elevated concentrations or reduced oxygen: positive-pressure SCBA or positive-pressure supplied-air respirator is recommended.
- High concentration or emergency rescue/evacuation: positive-pressure SCBA must be worn.
- Do NOT use filter-type respirators (due to asphyxiation risk at high concentrations; filter respirators do not supply oxygen).
Eye/face protection:
- General handling: safety goggles.
- When handling liquid or potential liquid exposure: chemical safety goggles or face shield must be worn to prevent frostbite.
Skin protection:
- Hand protection: cryogenic-insulated gloves (e.g., dry ice gloves, leather cold gloves) for liquid contact.
- Body protection: anti-static work clothing and anti-static footwear (clothing must comply with GB 12014 anti-static standard).
- Other: no smoking in work areas; use a buddy system when entering tanks or confined spaces, with rescue equipment available.
8.5 Hygiene measures
- Remove work clothing and wash skin thoroughly after work.
- Maintain good personal hygiene.
- Ensure eyewash and emergency shower are available in the workplace.
- Personnel with long-term propylene exposure should undergo periodic occupational health examinations.
9 Physical and chemical properties
9.1 Basic physical and chemical properties
| Appearance and odor | Colorless gas with a slight petroleum odor; gaseous at ambient temperature and pressure; colorless transparent liquid under pressure |
|---|---|
| Odor threshold | ~75 ppm (0.0075%); odor becomes noticeable above this concentration. Refrigerant-grade propylene is not odorized. |
| pH | Not applicable (gas) |
| Melting point / Freezing point | -185.2 °C (-301.4 °F) |
| Boiling point / Boiling range (101.3 kPa) | -47.7 °C (-53.9 °F) |
| Flash point | -108 °C (-162.4 °F) (closed cup) |
| Evaporation rate | Fast (liquid evaporates rapidly) |
| Flammability (gas) | Extremely flammable (Category 1A) |
| Explosive limits (upper/lower) | Upper 11.1% / Lower 2.0% (vol% in air) |
| Vapor pressure (25°C) | 1100 kPa (saturated vapor pressure) |
| Vapor density (air = 1) | 1.45 (heavier than air) |
| Relative density (liquid, 25°C) | 0.520 g/cm³ |
| Solubility | Slightly soluble in water (~200 mg/L at 25°C); soluble in ethanol, ether, and other organic solvents |
| Octanol/water partition coefficient (log P) | 1.77 |
| Auto-ignition temperature | 455 °C (851 °F) |
| Decomposition temperature | Stable at ambient temperature; may undergo pyrolysis and polymerization at high temperatures |
| Viscosity (gas, 25°C) | ~8.3 μPa·s |
| Surface tension (liquid, 25°C) | ~9.8 mN/m |
| Gas specific heat (25°C, constant pressure) | 1.52 kJ/(kg·°C) |
9.2 Thermodynamic properties
| Critical temperature | 91.8 °C (197.2 °F) |
|---|---|
| Critical pressure | 4600 kPa (4.60 MPa / 667.2 psia) |
| Critical density | 0.233 g/cm³ |
| Heat of vaporization (at boiling point) | 437 kJ/kg |
| Liquid specific heat (25°C) | 2.58 kJ/(kg·°C) |
| Henry's Law constant (25°C) | 7.4 × 10⁻² mol/(m³·Pa) |
9.3 Other safety data
| ASHRAE safety group | A3 (low toxicity, high flammability) |
|---|---|
| Ozone Depletion Potential (ODP) | 0 (does not deplete ozone layer; natural refrigerant) |
| Global Warming Potential (GWP, 100-yr) | ~2 (very low greenhouse effect; natural refrigerant) |
| Heat of combustion (lower heating value) | 45.8 MJ/kg |
| Minimum ignition energy | ~0.11 mJ (extremely low; static discharge can easily ignite) |
10 Stability and reactivity
10.1 Reactivity
Chemically stable under normal temperature and pressure conditions, but more reactive than alkanes (e.g., propane, isobutane) due to the C=C double bond. Can undergo addition and polymerization reactions.
10.2 Chemical stability
Stable under normal conditions of temperature and pressure. Avoid high temperatures, open flames, strong oxidizers, and polymerization catalysts.
10.3 Possibility of hazardous reactions
- May react violently with strong oxidizing agents (e.g., liquid oxygen, chlorine, hydrogen peroxide), with explosion risk.
- May undergo vigorous addition reactions with halogens (fluorine, chlorine, bromine) under light or high-temperature conditions.
- May undergo polymerization in the presence of catalysts (e.g., Ziegler-Natta catalysts, acid catalysts), forming polypropylene.
- Incomplete combustion at high temperatures produces carbon monoxide.
- May form explosive mixtures with strong oxidizing gases such as nitrogen dioxide.
10.4 Conditions to avoid
High temperature, open flame, sparks, static discharge, direct heat sources, cylinder overpressure. Avoid contact with polymerization catalysts. Avoid forming explosive gas-air mixtures.
10.5 Incompatible materials
Strong oxidizing agents (liquid oxygen, chlorine, hydrogen peroxide, potassium permanganate, nitrogen dioxide, etc.), halogens (fluorine, chlorine, bromine), strong acids, strong bases, polymerization catalysts (Ziegler-Natta catalysts, triethylaluminum, titanium tetrachloride, etc.)
10.6 Hazardous decomposition products
Carbon monoxide (CO) from incomplete combustion. Low-molecular-weight hydrocarbons and carbon black may form under high-temperature pyrolysis. Does not decompose under normal storage conditions.
10.7 Hazardous polymerization
Will not polymerize under normal ambient storage conditions. However, polymerization may occur in the presence of catalysts and under high-temperature/high-pressure conditions. Avoid contact with polymerization catalysts during storage; polymerization inhibitors may be added if necessary.
11 Toxicological information
11.1 Information on toxicological effects
Acute toxicity:
| Rat inhalation LC50 (4 hr) | >100,000 ppm (100,000 ppm, ~4 vol%; practically non-toxic; main hazards are asphyxiation and flammability) |
|---|---|
| Mouse inhalation LC50 (2 hr) | >100,000 ppm |
| Rabbit dermal LD50 | Not available (gaseous substance) |
Note: Propylene has extremely low acute toxicity. The rat 4-hour inhalation LC50 exceeds 100,000 ppm, classifying it as practically non-toxic. The primary health hazards are flammability/explosion, simple asphyxiation, and carcinogenic risk from long-term high-concentration exposure.
11.2 Skin irritation/corrosion
Gaseous state: no skin irritation. Liquid contact can cause frostbite (physical cryogenic injury), but is not a chemical corrosive. GHS classification: no skin corrosion/irritation classification (physical frostbite only).
11.3 Eye irritation/corrosion
Gaseous state: no eye irritation. Liquid contact can cause severe frostbite and corneal damage. GHS classification: no eye irritation classification (physical frostbite only).
11.4 Respiratory or skin sensitization
No sensitization reported. Available animal test data and human epidemiology data show no sensitization effect.
11.5 Germ cell mutagenicity
Propylene itself is not genotoxic. However, its in vivo metabolite propylene oxide is a direct-acting genotoxic carcinogen that can cause DNA damage and gene mutations. In vitro tests (Ames test, etc.) show that propylene itself has no mutagenic effect.
11.6 Carcinogenicity
- IARC (International Agency for Research on Cancer): Group 2B (Possibly carcinogenic to humans)
- ACGIH (American Conference of Governmental Industrial Hygienists): Category A3 (Confirmed animal carcinogen with unknown relevance to humans)
- EPA (U.S. Environmental Protection Agency): Not formally classified
Animal studies show that rats exposed to high concentrations of propylene (6,000~12,000 ppm, lifelong exposure) develop kidney tumors. The carcinogenic mechanism involves hepatic metabolism of propylene via cytochrome P450 enzymes to propylene oxide (a Category 2B carcinogen), which has direct genotoxicity. Under normal occupational exposure conditions (below TLV 500 ppm), carcinogenic risk is not significant. GHS classification: Carcinogenicity Category 1B (based on high-concentration long-term exposure conditions).
11.7 Reproductive toxicity
Available animal study data show no reproductive or developmental toxicity. No teratogenic effects observed at high-concentration exposure.
11.8 STOT-single exposure
- Narcotic effect (Category 3): Inhalation of high concentrations (>10,000 ppm) may cause central nervous system depression, manifested as dizziness, drowsiness, headache, and impaired consciousness.
- Cardiac effects: Very high-concentration exposure may cause cardiac arrhythmia, especially under stress.
- Asphyxiation: At high concentrations, displaces oxygen in air, causing hypoxia (symptoms appear when O₂ <19.5%; may be fatal when O₂ <6%).
11.9 STOT-repeated exposure
Repeated low-concentration exposure (below TLV) shows no significant target organ toxicity. However, long-term high-concentration exposure (animal studies ≥6,000 ppm) can cause kidney tumors. Periodic kidney function examinations are recommended for occupationally exposed populations.
11.10 Aspiration hazard
Not expected to cause aspiration pneumonia in gaseous form. High-concentration inhalation can cause CNS depression and hypoxic asphyxiation.
12 Ecological information
12.1 Ecotoxicity
| Fish acute toxicity (LC50, 96 hr) | Toxic to fish (GHS classification: Aquatic Acute 1) |
|---|---|
| Daphnia acute toxicity (EC50, 48 hr) | Detailed data not available |
| Algae growth inhibition (EC50, 72 hr) | Detailed data not available |
| Bacterial toxicity | Not available |
Note: Propylene has low water solubility, limiting actual aquatic exposure risk. The GHS aquatic toxicity classification is based on analog data.
12.2 Persistence and degradability
- Atmospheric degradation: Primarily degraded by reaction with hydroxyl radicals (·OH); atmospheric lifetime ~14 hours (much shorter than propane and isobutane; rapidly degrades).
- Biodegradability: Biodegradable under aerobic conditions.
- Hydrolysis: Not readily hydrolyzed at ambient temperature.
- Photodegradation: Rapidly photochemically degraded in the atmosphere.
12.3 Bioaccumulative potential
log P = 1.77. Low bioaccumulation potential (below the bioconcentration threshold of log P = 4.5).
12.4 Mobility in soil
Highly volatile in gaseous form. Low water solubility. Volatilizes readily to atmosphere when released to soil; does not persist in soil.
12.5 Results of PBT and vPvB assessment
Does not meet PBT (persistent, bioaccumulative, and toxic) / vPvB (very persistent and very bioaccumulative) criteria. Propylene's short atmospheric lifetime (~14 hours) means it is not a persistent substance.
12.6 Other adverse effects
- Ozone Depletion Potential (ODP): 0 (does not deplete the ozone layer; natural refrigerant)
- Global Warming Potential (GWP, 100-year time horizon): ~2 (relative to CO₂ = 1, extremely low greenhouse effect)
- R1270 is a natural organic working fluid (alkene hydrocarbon). Environmentally friendly with ODP=0 and very low GWP (~2), it is an eco-friendly alternative to freon-type refrigerants.
- Propylene degrades rapidly in the atmosphere (lifetime ~14 hours) and does not persist in the environment.
- Not a controlled substance under the Montreal Protocol; not a controlled greenhouse gas under the Kyoto Protocol (very low GWP and short atmospheric lifetime).
13 Disposal considerations
13.1 Waste treatment methods
Product/residues:
- Recovery and recycling (purification and reuse) is the preferred approach.
- Small amounts of unrecoverable residual liquid may be slowly vented to the atmosphere at a safe location (away from people, buildings, and ignition sources).
- Large quantities should be disposed of through a licensed hazardous waste treatment facility.
- High-temperature incineration with a safe combustion system is an acceptable method.
- Do NOT discharge liquid propylene to sewers, waterways, or soil.
- When venting, ensure no ignition sources are present and the area is well-ventilated.
Contaminated packaging:
- Empty cylinders must be returned to supplier or a qualified facility for disposal. Do not discard or cut empty cylinders.
- Empty cylinders with residual pressure and liquid are managed as hazardous waste.
- Never apply open flame heating, cutting, or welding to cylinders containing residual liquid.
13.2 Special precautions for disposal
- Refer to national and local regulations before disposal (e.g., Solid Waste Pollution Prevention and Control Law, Hazardous Waste Storage Pollution Control Standards, etc.).
- Personnel should wear appropriate personal protective equipment (see Section 8).
- Ensure good ventilation to prevent flammable gas accumulation.
- Disposal must be performed by a qualified and licensed facility.
- Disposal records should be maintained.
14 Transport information
14.1 UN number
1077 (Propylene, flammable gas)
14.2 UN proper shipping name
PROPYLENE
14.3 Transport hazard class(es)
Class 2.1 Flammable gas
14.4 Packing group
Not applicable (Class 2 gases are not assigned a packing group)
14.5 Packing mark / Hazard label
- Primary hazard label: Flammable gas (red, Class 2.1)
- Subsidiary hazard label: None
14.6 Methods and materials for containment and packaging
- Seamless or welded steel cylinders. Cylinders must comply with applicable national standards (e.g., GB 5099, GB 5100).
- Common package sizes: 10 kg, 20 kg, 50 kg cylinders; 400 kg, 800 kg, 1000 kg tanks.
- Filling coefficient must not exceed 0.43 kg/L (propylene).
- Cylinder valve outlet thread direction: left-hand thread for flammable gases.
14.7 Special requirements for different modes of transport
Road transport:
- Vehicles must have hazardous cargo transport license and be equipped with spark arrestors.
- Cylinders must have valve caps and safety rings in place.
- Cylinders generally laid flat with valves pointing in same direction; do not stack crosswise. Height must not exceed vehicle guardrail.
- Transport during early morning/evening in summer to avoid direct sunlight.
- Follow designated routes; do not stop in residential or densely populated areas.
- Vehicles must carry fire extinguishers and combustible gas detectors.
Rail transport:
- Prohibit hump shunting (no free-roll classification).
- Transport in boxcars; cylinders upright or laid flat and secured.
- Prohibit co-loading with oxidizers or self-igniting materials.
Marine transport (IMDG Code):
- UN 1077, Class 2.1
- Marine pollutant: No
- Stowage category: D (on deck only)
- Must be stowed away from heat sources and fire
Air transport (ICAO/IATA DGR):
- UN 1077, Class 2.1
- Flammable gas
- Passenger aircraft: Prohibited (unless meeting excepted quantity provisions)
- Cargo aircraft: Must comply with IATA DGR packaging requirements (subject to aviation authority approval)
14.8 Special precautions for user
- Do not co-transport with oxidizers, halogens, strong acids, strong bases, polymerization catalysts, or food/feed products.
- Vehicles must be equipped with appropriate fire extinguishing equipment and leak emergency response gear.
- Transport personnel must be specially trained and certified.
- Protect from sunlight, rain, and high temperature during transit.
- When stopping en route, stay away from fire, heat sources, and high-temperature areas.
- Exhaust pipes of vehicles carrying this product must be fitted with spark arrestors.
- Load and unload carefully to prevent damage to cylinders and fittings. No dropping or impact.
- Cylinders must be securely fastened during transport to prevent rolling and collision.
15 Regulatory information
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
China regulations:
- Regulation on the Safety Management of Hazardous Chemicals (State Council Decree No. 591)
- Catalog of Hazardous Chemicals (2015 edition): Listed (Class 2.1 flammable gas)
- GB 30000 series: Rules for classification and labelling of chemicals (GHS)
- GB/T 16483-2008: Content and order of sections in safety data sheet
- GBZ 2.1-2019: Occupational exposure limits for hazardous agents in the workplace
- Occupational Disease Prevention Law: Occupational health surveillance and prevention
- TSG 23-2021: Safety Technical Regulation for Gas Cylinders
- GB 50016: Code for Fire Protection Design of Buildings (Class A warehouse)
- GB 50058: Design Code for Electrical Installations in Explosive Atmospheres
- GB 9237: Refrigerating Systems and Heat Pumps - Safety and Environmental Requirements
- Production Safety Law of the People's Republic of China
- Fire Protection Law of the People's Republic of China (Class A flammable gas)
- Solid Waste Pollution Prevention and Control Law
International regulations:
- UN GHS (Globally Harmonized System of Classification and Labelling of Chemicals): 8th revised edition
- IARC (International Agency for Research on Cancer): Group 2B (Possibly carcinogenic to humans)
- ACGIH (American Conference of Governmental Industrial Hygienists): Category A3 (Confirmed animal carcinogen)
- Montreal Protocol: Not a controlled ozone-depleting substance (ODP = 0, natural refrigerant)
- Kyoto Protocol / Paris Agreement: Very low GWP (~2) and short atmospheric lifetime; not a priority controlled greenhouse gas
- EU REACH Regulation (EC 1907/2006): Registered substance
- EU CLP Regulation (EC 1272/2008): Classification, labelling and packaging regulation
- EU F-Gas Regulation (EC 517/2014): Not a fluorinated greenhouse gas; not subject to this regulation
- US EPA SNAP Program: Approved for refrigeration applications
- US OSHA HCS 2012: Hazard Communication Standard
- US DOT 49 CFR: Hazardous Materials Transportation Regulations
- ADR/RID: European Agreement concerning the International Carriage of Dangerous Goods by Road/Rail
- IMDG Code: International Maritime Dangerous Goods Code
- IATA DGR: International Air Transport Association Dangerous Goods Regulations
- ASHRAE Standard 34: Designation and Safety Classification of Refrigerants (Group A3)
15.2 Chemical safety assessment
Chemical Safety Assessment has not been carried out for this substance in the context of this SDS. Users should conduct their own assessment based on specific use conditions.
16 Other information
16.1 References
- NIOSH Pocket Guide to Chemical Hazards
- International Chemical Safety Card (ICSC) No. 0554
- NOAA CAMEO Chemicals Database
- PubChem Compound Database (CID 8252)
- IARC Monographs Volume 60 (Some Industrial Chemicals)
- ASHRAE Standard 34-2019 (Designation and Safety Classification of Refrigerants)
- ASHRAE Handbook - Refrigeration Systems and Applications
- GB/T 16483-2008 (Content and order of sections in safety data sheet for chemical products)
- GB 30000 series (Rules for classification and labelling of chemicals)
- United Nations GHS (Globally Harmonized System of Classification and Labelling of Chemicals), 8th revised edition
- GB 9237 (Refrigerating Systems and Heat Pumps - Safety and Environmental Requirements)
16.2 Abbreviations
| Abbreviation | Full term |
|---|---|
| SDS / MSDS | Safety Data Sheet / Material Safety Data Sheet |
| GHS | Globally Harmonized System of Classification and Labelling of Chemicals |
| CAS | Chemical Abstracts Service (registry number) |
| UN | United Nations (dangerous goods number) |
| ODP | Ozone Depletion Potential |
| GWP | Global Warming Potential |
| LC50 | Lethal Concentration, 50% |
| LD50 | Lethal Dose, 50% |
| TLV-TWA | Threshold Limit Value - Time-Weighted Average |
| PEL | Permissible Exposure Limit |
| SCBA | Self-Contained Breathing Apparatus |
| PBT | Persistent, Bioaccumulative, and Toxic |
| LEL | Lower Explosive Limit |
| UEL | Upper Explosive Limit |
| BLEVE | Boiling Liquid Expanding Vapor Explosion |
| HC | Hydrocarbon |
| STOT | Specific Target Organ Toxicity |
| IARC | International Agency for Research on Cancer |
| ACGIH | American Conference of Governmental Industrial Hygienists |
| PID | Photoionization Detector |
16.3 Disclaimer
This Safety Data Sheet (SDS) has been prepared in accordance with the UN GHS standard and applicable regulatory requirements. The information contained herein is based on publicly available chemical databases, technical literature, and national standards, and is believed to be accurate and complete as of the date of issuance. However, no warranty, express or implied, is made as to the absolute accuracy, completeness, or reliability of the information. R1270 is an A3 extremely flammable refrigerant. Explosion-proof safety regulations must be strictly followed during use, storage, and transport. Propylene is classified by IARC as Group 2B (possibly carcinogenic to humans, based on high-concentration long-term exposure animal study evidence). Personnel with long-term exposure should take appropriate occupational protection measures and undergo periodic medical examinations. Users should verify the applicability of the information for their specific use conditions and refer to the official SDS provided by the manufacturer/supplier for compliance purposes. The information in this document may be updated as new research findings and regulatory changes become available; periodic review of the latest version is recommended.