1 Identification
1.1 Product identifier
| Chemical name | 1-Chloro-1,1-difluoroethane |
|---|---|
| Common names / synonyms | R142b, HCFC-142b, HCFC142b, Difluorochloroethane, Freon 142b, Genetron 142b (CH₃CClF₂) |
| CAS number | 75-68-3 |
| UN number | 2517 (flammable liquefied gas) |
| Dangerous goods code | Class 2.1 Flammable gas |
| Molecular formula | C2H3ClF2 (CH3CClF2) |
| Molecular weight | 100.50 g/mol |
| Recommended use | HCFC flammable refrigerant, foam blowing agent, mixed refrigerant component, resin blowing agent, etc. |
1.2 Details of the supplier of the safety data sheet
| Supplier name | Hangzhou Wula Chemical Co., Ltd. |
|---|---|
| Address | No. 7 Longtan Road, Yuhang District, Hangzhou, Zhejiang Province, China |
| Postal code | 311100 |
| Telephone | +86-571-87024025 |
| Fax | +86-571-87024025 |
| safety@wulachem.cn |
1.3 Emergency telephone number
National Chemical Emergency Hotline (China): +86-532-83889090 (24 hours)
Supplier Emergency Contact: +86-571-87024025
2 Hazards identification
2.1 GHS classification
- Flammable gas (Physical hazard) — Category 1A
- Compressed gas (Physical hazard) — Liquefied gas
- Specific target organ toxicity - single exposure (Health hazard, narcotic effect) — Category 3
Note: This substance is ASHRAE Group A2 (flammable, low toxicity) and is an HCFC flammable refrigerant. Explosive limits are 6.3%~15.0% by volume in air. Special explosion-proof measures are required. Frostbite from liquid contact is a physical low-temperature injury.
2.2 GHS label elements
Signal word: Danger
Hazard statements:
- H220 Extremely flammable gas.
- H280 Contains gas under pressure; may explode if heated.
- H336 May cause drowsiness or dizziness.
Precautionary statements:
- P102 Read and understand all safety precautions before handling.
- P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking.
- P271 Use only outdoors or in a well-ventilated area.
- P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
- P312 Call a POISON CENTER or doctor/physician if you feel unwell.
- P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
- P381 Eliminate all ignition sources if safe to do so.
- P403 Store in a well-ventilated place.
- P410+P403 Protect from sunlight. Store in a well-ventilated place.
- P405 Store locked up.
2.3 Other hazards
- Vapor is heavier than air (~3.5 times) and may spread long distances along the ground; may ignite and flash back from distant ignition sources.
- Flammable gas with explosive limits of 6.3%~15.0% by volume in air; auto-ignition temperature 632°C.
- Decomposes at high temperatures producing toxic and corrosive gases (hydrogen fluoride, hydrogen chloride, carbonyl fluoride, etc.).
- Cylinders may rupture or burst when heated due to increased internal pressure.
- HCFC-class ozone-depleting substance (ODP=0.065); controlled under the Montreal Protocol and being phased out globally.
3 Composition/information on ingredients
3.1 Substance/mixture
This product is a pure substance.
3.2 Composition information
| Component name | CAS No. | Concentration (by mass) |
|---|---|---|
| 1-Chloro-1,1-difluoroethane | 75-68-3 | ≥99.5% |
3.3 Impurity information
| Impurity | Superior Grade | First Grade |
|---|---|---|
| Acidity (as HCl) | ≤0.1 ppm | ≤1 ppm |
| Moisture | ≤10 ppm | ≤20 ppm |
| Evaporation residue | ≤100 ppm | ≤100 ppm |
| Non-condensable gas (25°C, vol%) | ≤1.5% | ≤1.5% |
| Chloride | Pass | Pass |
4 First aid measures
4.1 Description of necessary first aid measures
General advice: Remove victim from contaminated area immediately. Keep warm and at rest. Show this SDS to attending physician.
Inhalation:
- Move victim to fresh air immediately. Keep airway clear.
- Administer oxygen if breathing is difficult.
- If not breathing, give artificial respiration (preferably with bag-valve-mask or pocket mask; avoid mouth-to-mouth).
- If no pulse, start cardiopulmonary resuscitation (CPR) immediately.
- Keep victim warm and at rest. Monitor condition closely.
- Seek medical attention immediately.
Skin contact (frostbite):
- Immediately flush affected area with large amounts of lukewarm water (37–40°C) to promote rewarming.
- Do NOT use hot water (>40°C) or direct heat (e.g., electric heaters).
- Do NOT rub or massage frostbitten area; this may worsen tissue damage.
- Carefully remove frozen clothing. If clothing sticks to skin, do NOT pull it off; cut around it.
- Cover with sterile dressing.
- Seek medical attention immediately.
Eye contact:
- Immediately hold eyelids open and rinse thoroughly with plenty of water or normal saline for at least 15 minutes.
- Ensure complete irrigation of all eye surfaces by lifting upper and lower lids.
- Remove contact lenses if present and easily removable.
- Seek medical attention immediately, preferably from an ophthalmologist.
Ingestion:
Not applicable. This substance is a gas at ambient temperature; ingestion exposure is not expected.
4.2 Most important symptoms and effects, both acute and delayed
- Acute inhalation: dizziness, drowsiness, headache, nausea, ataxia, loss of consciousness, cardiac arrhythmia.
- Skin contact (liquid): frostbite (pale, hard skin, pain, blistering).
- Eye contact (liquid): severe frostbite, corneal damage, visual impairment.
- Fire/explosion: combustion products can cause chemical lung injury.
4.3 Indication of any immediate medical attention and special treatment needed
- Symptomatic and supportive therapy. Maintain airway; administer oxygen if needed.
- Monitor cardiac function; high-concentration exposure may cause arrhythmias.
- Avoid catecholamine drugs (e.g., epinephrine/adrenaline) — they may increase myocardial sensitivity to fluorocarbons and precipitate ventricular fibrillation.
- Treat frostbite with standard protocols: lukewarm water (37–40°C) rewarming. Do NOT use dry heat or massage.
- If combustion products were inhaled, monitor for airway injury and hydrogen fluoride poisoning.
5 Firefighting measures
5.1 Extinguishing media
Suitable extinguishing media: Dry chemical, carbon dioxide. For large fires, use water spray, foam, or regular fire-fighting agents. Note: For gas fires, do NOT extinguish the flame unless the gas source can be safely shut off; continued leakage may accumulate and cause a more severe explosion.
Unsuitable extinguishing media: Direct water jet (may spread the gas cloud).
5.2 Special hazards arising from the substance or mixture
- Flammable gas with explosive limits 6.3%~15.0% by volume in air; auto-ignition temperature 632°C.
- Vapor is heavier than air and may spread long distances along the ground; may ignite and flash back from distant ignition sources.
- Thermal decomposition at high temperatures produces toxic and corrosive gases: hydrogen fluoride (HF), hydrogen chloride (HCl), and carbonyl fluoride (COF₂).
- Cylinders may rupture or burst when heated; flying fragments may cause injury.
- May react violently with strong oxidizing agents.
5.3 Hazardous combustion products
Hydrogen fluoride (HF), hydrogen chloride (HCl), carbonyl fluoride (COF₂), carbon monoxide (CO), carbon dioxide (CO₂), and other fluorinated/chlorinated compounds.
5.4 Advice for firefighters
- Firefighters must wear positive-pressure self-contained breathing apparatus (SCBA) and full protective fire-resistant clothing.
- If safe to do so, shut off gas source. If gas source cannot be shut off, do not extinguish the flame at the leak point.
- Cool containers with water spray from a safe distance until fire is extinguished.
- Immediately evacuate if containers show discoloration or if pressure relief devices begin to vent.
- Isolate the area; keep unauthorized personnel out.
- Avoid direct water jets on leaking liquefied gas.
- Prevent fire-fighting runoff from entering waterways and sewers.
6 Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
- Evacuate personnel from the leak area to upwind locations immediately. Establish a perimeter and restrict access.
- Eliminate all ignition sources (prohibit use of spark-generating equipment and tools).
- Emergency responders should wear SCBA, anti-static work clothing, cryogenic gloves, and eye protection.
- Enter from upwind direction.
- Stop leak if it can be done safely.
- Do not touch or walk through spilled material.
- Maintain emergency contact personnel for external support.
6.2 Environmental precautions
- Prevent gas from entering sewers, basements, or confined spaces (explosion hazard).
- Ventilate the area to accelerate dispersion.
- Minimize releases to control ozone-depleting substance emissions; recover whenever possible.
- Avoid release to atmosphere, waterways, or soil.
6.3 Methods and materials for containment and cleaning up
- Small leak: Increase ventilation to accelerate gas dispersion. Eliminate all nearby ignition sources. Monitor flammable gas concentration (below 10% of LEL).
- Large leak:
- Immediately establish a restricted zone and evacuate downwind personnel.
- Close source valve if safe to do so.
- Recover using dedicated gas recovery equipment.
- If recovery is not possible, use water fog/mist to dilute and reduce vapor concentration.
- Cylinder leak: Move cylinder to a well-ventilated safe area and vent slowly. If valve cannot be closed, contact supplier for professional handling.
6.4 Reference
See Section 8 (Exposure controls/personal protection) and Section 13 (Disposal considerations).
7 Handling and storage
7.1 Precautions for safe handling
- Handle in closed systems with adequate natural ventilation or local exhaust.
- Personnel must be specially trained and strictly follow operating procedures. Certified personnel only.
- Prevent gas leakage into workplace atmosphere.
- Keep away from fire, heat sources, and open flames. No smoking in work areas.
- Use explosion-proof ventilation systems and equipment.
- Avoid sparks; use explosion-proof tools and wear anti-static work clothing.
- Avoid contact with oxidizers and reactive metals.
- Handle cylinders carefully; do not drop, slide, roll, or bump cylinders.
- Equip area with leak emergency response equipment.
- Wear insulated gloves and eye/face protection when handling liquid to prevent frostbite.
- Periodically inspect cylinders, valves, and piping for leaks.
- Cylinders and piping must be grounded to prevent static electricity accumulation.
7.2 Conditions for safe storage, including any incompatibilities
- Store in a cool, dry, well-ventilated flammable gas warehouse.
- Storage temperature should not exceed 30°C. Keep away from fire, heat sources, and direct sunlight.
- Store separately from oxidizers, reactive metals, halogens, and other incompatible materials.
- Storage area should be equipped with leak emergency response equipment and suitable containment materials.
- Cylinders must be stored upright with valve caps and safety rings in place, properly secured to prevent falling.
- Use explosion-proof lighting and ventilation systems.
- Prohibit use of equipment and tools that can generate sparks.
- Post clear "Flammable Gas" safety warning signs in storage areas.
- Implement two-person receiving/issuing and two-person custody system.
- Warehouse must be equipped with combustible gas detection and alarm devices.
7.3 Specific end uses
For industrial use only. Personnel must be professionally trained. Primarily used as an HCFC flammable refrigerant, foam blowing agent, and mixed refrigerant component. Do not use for direct food contact, medical inhalation, or other unapproved applications. Note: This substance is a controlled HCFC under the Montreal Protocol and is being phased out globally.
8 Exposure controls/personal protection
8.1 Control parameters
| China OEL (Occupational Exposure Limit) | No established legal limit. Recommended reference: ACGIH TLV 1000 ppm (TWA, 8 hr) |
|---|---|
| ACGIH TLV-TWA (USA) | 1000 ppm (approx. 4100 mg/m³), 8-hour time-weighted average |
| OSHA PEL-TWA (USA) | Not established (refer to ACGIH) |
| Biological limit value | Not established |
Note: Per GBZ 2.1-2019, this substance is not currently listed in the Chinese OEL table. However, flammability hazard must be noted; workplace concentration must remain far below the lower explosive limit (LEL = 6.3%).
8.2 Exposure monitoring methods
Gas chromatography with flame ionization detection (GC-FID) or mass spectrometry (GC-MS); non-dispersive infrared (NDIR) analysis; combustible gas detectors.
8.3 Appropriate engineering controls
- Enclosed process design with general ventilation or local exhaust.
- Provide safety shower and eyewash station.
- Install combustible gas detection alarms in areas where leaks may occur (alarm set point not exceeding 25% of LEL).
- Use explosion-proof electrical equipment and lighting.
- All metal equipment, piping, and cylinders must be reliably grounded.
8.4 Individual protection measures
Respiratory protection:
- Normal conditions (below exposure limit): no special protection required.
- Elevated concentrations: half-face respirator with organic vapor cartridge is recommended.
- High concentration or emergency rescue/evacuation: positive-pressure self-contained breathing apparatus (SCBA) must be worn.
Eye/face protection:
- General handling: no special protection required.
- When handling liquid or potential liquid exposure: chemical safety goggles or face shield must be worn to prevent frostbite.
Skin protection:
- Hand protection: cryogenic-insulated gloves for liquid contact.
- Body protection: anti-static work clothing; cold-resistant clothing for liquid contact.
- Other: no smoking in work areas; wear anti-static shoes; use a buddy system when entering tanks or confined spaces.
8.5 Hygiene measures
- Remove contaminated clothing and wash skin thoroughly after work.
- Maintain good personal hygiene.
- Ensure eyewash and emergency shower are available in the workplace.
9 Physical and chemical properties
9.1 Basic physical and chemical properties
| Appearance and odor | Colorless gas with a faint ethereal odor; gaseous at ambient temperature and pressure; colorless transparent liquid under pressure |
|---|---|
| Odor threshold | Not available (faint ether-like odor) |
| pH | Not applicable (gas) |
| Melting point / Freezing point | -131 °C (-203.8 °F) |
| Boiling point / Boiling range (101.3 kPa) | -9.2 °C (15.4 °F) |
| Flash point | None (gas, but is a flammable gas) |
| Evaporation rate | Not available |
| Flammability (gas) | Flammable (Category 1A) |
| Explosive limits (upper/lower, vol% in air) | Upper 15.0% / Lower 6.3% |
| Vapor pressure (25°C) | 340 kPa (saturated vapor pressure) |
| Vapor density (air = 1) | ~3.5 (heavier than air) |
| Relative density (liquid, 25°C) | 1.122 g/cm³ |
| Solubility | Slightly soluble in water; soluble in ethanol, ether, and other organic solvents |
| Octanol/water partition coefficient (log P) | ~1.6 |
| Auto-ignition temperature | 632 °C (1169.6 °F) |
| Decomposition temperature | >300 °C onset of thermal decomposition |
| Viscosity (liquid, 25°C) | ~0.30 mPa·s |
| Surface tension (liquid, 25°C) | ~10.0 mN/m |
9.2 Thermodynamic properties
| Critical temperature | 137.1 °C (278.8 °F) |
|---|---|
| Critical pressure | 4120 kPa (4.12 MPa / 598 psia) |
| Critical density | 0.43 g/cm³ |
| Heat of vaporization (at boiling point) | 222 kJ/kg |
| Liquid specific heat (25°C) | 1.28 kJ/(kg·°C) |
| Henry's Law constant (25°C) | Not available |
9.3 Other safety data
| ASHRAE safety group | A2 (low toxicity, flammable) |
|---|---|
| Ozone Depletion Potential (ODP) | 0.065 (ozone-depleting substance; see Section 12.6) |
| Global Warming Potential (GWP, 100-yr) | 2300 (greenhouse gas; see Section 12.6) |
10 Stability and reactivity
10.1 Reactivity
Chemically stable under normal temperature and pressure, but is a flammable gas that may burn or explode upon contact with ignition sources or high temperatures.
10.2 Chemical stability
Stable under normal conditions of temperature and pressure, but must be kept away from fire and heat sources.
10.3 Possibility of hazardous reactions
- May form explosive mixtures with air (explosive limits 6.3%~15.0%).
- Thermal decomposition at high temperatures produces toxic hydrogen fluoride, hydrogen chloride, and carbonyl fluoride.
- May react with alkali metals, alkaline earth metals, and aluminum powder under high temperature or specific conditions.
- May react violently with strong oxidizing agents.
10.4 Conditions to avoid
High temperature, open flame, sparks, electrostatic discharge, direct heat sources, cylinder overpressure
10.5 Incompatible materials
Reactive metals (sodium, potassium, calcium, aluminum powder, magnesium powder, etc.), strong oxidizing agents, halogens
10.6 Hazardous decomposition products
Hydrogen fluoride (HF), hydrogen chloride (HCl), carbonyl fluoride (COF₂), carbon monoxide (CO), and other fluorinated/chlorinated compounds
10.7 Hazardous polymerization
Will not occur.
11 Toxicological information
11.1 Information on toxicological effects
Acute toxicity:
| Rat inhalation LC50 (4 hr) | 150,000 ppm (low toxicity) |
|---|---|
| Rabbit dermal LD50 | Not available (gaseous substance) |
11.2 Skin irritation/corrosion
Liquid contact can cause frostbite (physical injury), but is not a chemical corrosive.
11.3 Eye irritation/corrosion
Liquid contact can cause severe frostbite and corneal damage.
11.4 Respiratory or skin sensitization
No sensitization reported. Available animal test data and human epidemiology data show no sensitization effect.
11.5 Germ cell mutagenicity
In vitro and in vivo tests (Ames test, chromosome aberration test, etc.) show no mutagenic effect.
11.6 Carcinogenicity
Insufficient evidence for carcinogenicity.
- IARC (International Agency for Research on Cancer): Not listed
- ACGIH (American Conference of Governmental Industrial Hygienists): Category A4 (Not classifiable as a human carcinogen)
- EPA (U.S. Environmental Protection Agency): Not classified
11.7 Reproductive toxicity
Animal studies show no significant reproductive or developmental toxicity at high concentrations. No human reproductive toxicity data available.
11.8 STOT-single exposure
- Narcotic effect (Category 3): Inhalation of high concentrations may cause central nervous system depression, manifested as dizziness, drowsiness, headache, and impaired consciousness.
- Cardiac effects: High-concentration exposure may cause cardiac arrhythmia, especially under stress or exercise (catecholamine sensitization).
11.9 STOT-repeated exposure
Repeated low-concentration exposure shows no significant target organ toxicity. Long-term animal inhalation studies have not shown clear organ damage.
11.10 Aspiration hazard
Not expected to cause aspiration pneumonia in gaseous form. However, high-concentration inhalation can cause CNS depression and cardiac sensitization. Inhalation of combustion products (hydrogen fluoride, etc.) can cause severe airway injury.
12 Ecological information
12.1 Ecotoxicity
| Fish acute toxicity (LC50, 96 hr) | >100 mg/L (low toxicity to fish) |
|---|---|
| Daphnia acute toxicity (EC50, 48 hr) | >100 mg/L |
| Algae growth inhibition (EC50, 72 hr) | Not available |
| Bacterial toxicity | Not available |
12.2 Persistence and degradability
- Atmospheric degradation: Primarily degraded by reaction with hydroxyl radicals; atmospheric lifetime ~17 years.
- Biodegradability: Poorly biodegradable (not readily degraded by microorganisms).
- Hydrolysis: Not readily hydrolyzed at ambient temperature.
- Photodegradation: Can be photochemically degraded in the atmosphere.
12.3 Bioaccumulative potential
log P = 1.6. Low bioaccumulation potential (below the bioconcentration threshold of log P = 4.5).
12.4 Mobility in soil
Highly volatile in gaseous form. Low water solubility. High mobility. Volatilizes readily to atmosphere when released to soil.
12.5 Results of PBT and vPvB assessment
Does not meet PBT (persistent, bioaccumulative, and toxic) / vPvB (very persistent and very bioaccumulative) criteria.
12.6 Other adverse effects
- Ozone Depletion Potential (ODP): 0.065 (HCFC-class ozone-depleting substance; causes ozone layer damage)
- Global Warming Potential (GWP, 100-year time horizon): 2300 (relative to CO₂ = 1, significant greenhouse effect)
- This substance is a controlled substance under the Montreal Protocol (HCFC class) and is being phased out globally.
- Large releases significantly impact the ozone layer and global warming; emissions should be strictly controlled with priority on recovery and reuse.
13 Disposal considerations
13.1 Waste treatment methods
Product/residues:
- Do NOT release directly to atmosphere (ozone-depleting substance, flammable gas).
- Recovery and recycling (purification and reuse) is the preferred approach.
- If recovery is not feasible, dispose of through a licensed hazardous waste treatment facility.
- High-temperature incineration with alkaline scrubber for fluoride and chloride removal is an acceptable method.
- Do not discharge to sewers, waterways, or soil.
Contaminated packaging:
- Empty cylinders must be returned to supplier or a qualified facility for disposal. Do not discard or cut empty cylinders.
- Empty cylinders with residual pressure and flammable gas are managed as hazardous waste.
13.2 Special precautions for disposal
- Refer to national and local regulations before disposal (e.g., Solid Waste Pollution Prevention and Control Law, Ozone-Depleting Substances Management Regulations, etc.).
- Personnel should wear appropriate personal protective equipment (see Section 8).
- Ensure good ventilation and eliminate all ignition sources to prevent flammable gas accumulation.
- Disposal must be performed by a qualified and licensed facility.
- Disposal records should be maintained.
14 Transport information
14.1 UN number
2517 (1-Chloro-1,1-difluoroethane, flammable liquefied gas)
14.2 UN proper shipping name
1-CHLORO-1,1-DIFLUOROETHANE
14.3 Transport hazard class(es)
Class 2.1 Flammable gas
14.4 Packing group
Not applicable (Class 2 gases are not assigned a packing group)
14.5 Packing mark / Hazard label
- Primary hazard label: Flammable gas (red, Class 2.1)
- Subsidiary hazard label: None
14.6 Methods and materials for containment and packaging
- Seamless steel cylinders. Cylinders must comply with applicable national standards (e.g., GB 5099).
- Common package sizes: 13.6 kg, 50 kg, 100 kg, 400 kg, 800 kg cylinders and ISO tank containers.
- Cylinder valve outlet thread direction: left-hand thread for flammable gases.
14.7 Special requirements for different modes of transport
Road transport:
- Vehicles must have hazardous cargo transport license; exhaust pipes must be fitted with spark arrestors.
- Cylinders must have valve caps and safety rings in place.
- Cylinders generally laid flat with valves pointing in same direction; do not stack crosswise. Height must not exceed vehicle guardrail.
- Transport during early morning/evening in summer to avoid direct sunlight.
- Follow designated routes; do not stop in residential or densely populated areas.
- Must be equipped with anti-static grounding devices.
Rail transport:
- Prohibit hump shunting (no free-roll classification).
- Transport in boxcars; cylinders upright or laid flat and secured.
Marine transport (IMDG Code):
- UN 2517, Class 2.1
- Marine pollutant: No
- Stowage category: E (on deck only)
Air transport (ICAO/IATA DGR):
- UN 2517, Class 2.1
- Flammable gas
- Forbidden on passenger aircraft / cargo aircraft only (subject to quantity limits)
14.8 Special precautions for user
- Do not co-transport with oxidizers, reactive metals, halogens, or food/feed products.
- Vehicles must be equipped with appropriate fire extinguishing equipment and leak emergency response gear.
- Transport personnel must be specially trained and certified.
- Protect from sunlight, rain, and high temperature during transit; keep away from fire and heat sources.
- When stopping en route, stay away from fire, heat sources, and high-temperature areas.
- Exhaust pipes of vehicles carrying this product must be fitted with spark arrestors.
- Load and unload carefully to prevent damage to cylinders and fittings.
- Cylinders and vehicles must be reliably grounded during transport to prevent static electricity accumulation.
15 Regulatory information
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
International regulations:
- UN GHS (Globally Harmonized System of Classification and Labelling of Chemicals): 8th revised edition
- Montreal Protocol: Controlled ozone-depleting substance (HCFC class, ODP=0.065); being phased out globally
- Kyoto Protocol / Paris Agreement: Listed as greenhouse gas (GWP=2300, significant greenhouse effect)
- EU REACH Regulation (EC 1907/2006): Registered substance
- EU CLP Regulation (EC 1272/2008): Classification, labelling and packaging regulation
- EU F-Gas Regulation (EC 517/2014): Fluorinated greenhouse gas control
- US EPA SNAP Program: Approved for specific applications (being phased out)
- US OSHA HCS 2012: Hazard Communication Standard
- US DOT 49 CFR: Hazardous Materials Transportation Regulations
- ADR/RID: European Agreement concerning the International Carriage of Dangerous Goods by Road/Rail
- IMDG Code: International Maritime Dangerous Goods Code
- IATA DGR: International Air Transport Association Dangerous Goods Regulations
15.2 Chemical safety assessment
Chemical Safety Assessment has not been carried out for this substance in the context of this SDS. Users should conduct their own assessment based on specific use conditions.
16 Other information
16.1 References
- NIOSH Pocket Guide to Chemical Hazards
- International Chemical Safety Card (ICSC)
- NOAA CAMEO Chemicals Database
- PubChem Compound Database
- ASHRAE Handbook - Refrigeration Systems and Applications
- GB/T 16483-2008 (Content and order of sections in safety data sheet for chemical products)
- GB 30000 series (Rules for classification and labelling of chemicals)
- United Nations GHS (Globally Harmonized System of Classification and Labelling of Chemicals), 8th revised edition
- Montreal Protocol on Substances that Deplete the Ozone Layer and its amendments
16.2 Abbreviations
| Abbreviation | Full term |
|---|---|
| SDS / MSDS | Safety Data Sheet / Material Safety Data Sheet |
| GHS | Globally Harmonized System of Classification and Labelling of Chemicals |
| CAS | Chemical Abstracts Service (registry number) |
| UN | United Nations (dangerous goods number) |
| ODP | Ozone Depletion Potential |
| GWP | Global Warming Potential |
| HCFC | Hydrochlorofluorocarbon |
| LC50 | Lethal Concentration, 50% |
| LD50 | Lethal Dose, 50% |
| TLV-TWA | Threshold Limit Value - Time-Weighted Average |
| PEL | Permissible Exposure Limit |
| SCBA | Self-Contained Breathing Apparatus |
| PBT | Persistent, Bioaccumulative, and Toxic |
| LEL/UEL | Lower/Upper Explosive Limit |
| STOT | Specific Target Organ Toxicity |
16.3 Disclaimer
This Safety Data Sheet (SDS) has been prepared in accordance with the UN GHS standard and applicable regulatory requirements. The information contained herein is based on publicly available chemical databases, technical literature, and national standards, and is believed to be accurate and complete as of the date of issuance. However, no warranty, express or implied, is made as to the absolute accuracy, completeness, or reliability of the information. Users should verify the applicability of the information for their specific use conditions and refer to the official SDS provided by the manufacturer/supplier for compliance purposes. The information in this document may be updated as new research findings and regulatory changes become available; periodic review of the latest version is recommended.